9 Viewing traps in RHEV-M
HP OneView for RHEV can populate the RHEV-M event database with information from SNMP
traps generated by HP hardware. The benefit of populating the traps in the RHEV-M database is
to facilitate notification and identification of hardware error conditions or failures.
To view these traps, click the Events tab in the RHEV-M console.
Events populated by HP OneView for RHEV include:
• iLO traps (e.g. for power failure, iLO reset, health degradation)
• Onboard Administrator traps
• Virtual Connect module traps
NOTE: For traps to be populated in the RHEV-M database, each entity must first be configured
with RHEV-M as a destination. To configure each entity trap:
• iLO traps
◦ Access the iLO Administration>Management>SNMP settings.
◦ Select Agentless Management or SNMP Pass-thru depending on the iLO version, and
then select the Add RHEV-M as SNMP trap destination.
• Onboard Administrator traps
◦ Access the Onboard Administrator>Enclosure Information>Enclosure settings, and then
select SNMP settings.
◦ Click the New button, and then select the Add RHEV-M as SNMPtrap destination.
NOTE: The default SNMP Community String is “public.”
Virtual Connect module traps
◦ If a Virtual Connect module is managed by HP OneView, access HP OneView
appliance>Settings>Edit Appliance, and then select Add RHEV-M as SNMP trap destination.
NOTE: The entity must be discovered in RHEV-M to receive traps from that entity.
33