168
Software Fixes in Release K.11.12 - K.13.49
Release K.12.16
Rate-Limiting (PR_1000420720) — Rate limiting is broken beyond 9.5 Mbps. For any rate
limit set to more than 9.5 Mbps, the actual rate drops to 1 Mbps.
Release K.12.16
The following problems were resolved in release K.12.16.
Crash (PR_1000415621) — Removing a VLAN that has OSPF configured may cause the
switch to crash with a message similar to:
NMI event HW:IP=0x0084a0a4 MSR:0x00029210 LR:0x00513ee4 Task='eRou-
teCtrl' Task ID=0x89658b0'
Crash (PR_1000428582) — Typing non-alphanumeric characters at the CLI prompt may
cause the switch to crash with a message similar to:
PPC Data Storage (Bus Error) exception vector 0x300:Stack
Frame=0x08e36878 HW Addr=0x00b4f2ec IP=0x0018a974 Task='mSess1' Task
ID=0x0fp: 0x18020800 sp:
Release K.12.17
The following problems were resolved in release K.12.17.
STP (PR_1000420442) — The switch erroneously allows configuration of spanning tree
parameters on an interface that is a member of a trunk (link aggregation group), which
creates an invalid configuration.
CLI (PR_1000429474) — The "all" parameter is missing from the "password" command.
Radius (PR_1000432556) — When DHCP snooping is enabled on the client VLAN, and the
client is on a VLAN other than the default VLAN, the Framed-IP-Address attribute is not added
to the RADIUS accounting packet as it should be.
Crash (PR_1000416453) — Execution of the "show tech" command in an SSH session may
cause the switch to crash with a message similar to:
Software exception - Assert in pmgr_util.c:1155 -- in 'mSess2', task
ID = 0x85adf60