Hp Virtual Connect Enterprise Manager Software Manual de usuario

Busca en linea o descarga Manual de usuario para Software Hp Virtual Connect Enterprise Manager Software. HP Virtual Connect Enterprise Manager Software User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 111
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
HP Virtual Connect Enterprise Manager
User Guide
HP Part Number: 460924-006
Published: January 2010, Sixth Edition
Vista de pagina 0
1 2 3 4 5 6 ... 110 111

Indice de contenidos

Pagina 1 - User Guide

HP Virtual Connect Enterprise ManagerUser GuideHP Part Number: 460924-006Published: January 2010, Sixth Edition

Pagina 3 - Table of Contents

After a server profile failover, some connections defined in the server profile are notfunctionalVCEM cannot identify if all Fibre Channel and Etherne

Pagina 4 - 4 Table of Contents

Create VC Domain Group or Add VC Domain to VC Domain Group operations failand the message "An invalid boot LUN was entered. Check the storage arr

Pagina 5 - Table of Contents 5

5. Click the VC Domains tab, for each VC Domain with "Configuration Mismatch" status, click VC DomainMaintenance. To confirm the resynchroni

Pagina 6 - 6 Table of Contents

14 HP services and technical supportHP offers a number of software support services, many of which are provided to our customers at no additionalcharg

Pagina 8

Glossarybays A device bay where the server blade is connected. HP BladeSystem c7000 Enclosure has a totalof 16 device bays and HP BladeSystem c3000 En

Pagina 9 - About this document

hardware status The operating state of SNMP-based systems. A hardware status is determined by polling SNMPinformation from the system. Status is defin

Pagina 10

Simple NetworkManagementProtocol (SNMP)One of the management protocols supported by . Traditional management protocol usedextensively by networking sy

Pagina 12 - Architectural overview

IndexAadding a VC Domain to a VC Domain Group, 32adding custom MAC address ranges, 69adding custom WWN address range, 72adding or removing VC modules

Pagina 13 - Managing HP Virtual Connect

1 IntroductionHP Virtual Connect Enterprise Manager (VCEM) centralizes network connectivity and workload mobility forHP BladeSystem servers that use V

Pagina 14 - VCEM operations

configuring multiple networks, 54configuring network port speed, 55configuring the target boot LUN, 53copying and assigning a profile to a bay, 57crea

Pagina 15

VVC Domain Groupcanceling a VC Domain Group maintenance task, 46creating a VC Domain Group, 44deleting a VC Domain Group, 46maintaining a VC Domain fr

Pagina 16

• Increase productivity and server-to-administrator ratios.• Release LAN and SAN administrators from routine server-centric tasks.• VCEM scales across

Pagina 17 - Installing VCEM

NIC or HBA addresses. Even if a server is replaced, the MAC and WWN assignments for the enclosure willremain the same, and changes are invisible to th

Pagina 18 - Understanding HP SIM security

HP Virtual Connect Enterprise ManagerVCEM is HP’s primary application for managing Virtual Connect environments. It provides centralizedgroup-based ma

Pagina 19 - VCEM home page

Figure 1-2 Virtual Connect Enterprise Manager operationsVCEM centralizes Virtual Connect infrastructure management and increases productivity.Setup an

Pagina 21 - 3 Managing VC Domains

2 Installing and configuring VCEMThis chapter describes how to install and configure VCEM.IMPORTANT: This guide assumes that you have previously insta

Pagina 22 - 22 Managing VC Domains

3. (Optional) If you are installing VCEM as part of the HP Insight Software suite, after performing an HPSIM discovery, access the HP Managed System S

Pagina 23 - VC Domains 23

VCEM home pageThe following screenshot shows the VCEM home page.Figure 2-1 VCEM home pageVCEM home page 19

Pagina 24 - 24 Managing VC Domains

© Copyright 2007, 2009 Hewlett-Packard Development Company, L.P.Legal NoticesConfidential computer software. Valid license from HP required for posses

Pagina 26 - 26 Managing VC Domains

3 Managing VC DomainsVC DomainsThis section describes how to use VCEM to manage VC Domains.On the VC Domains page, you can filter the VC Domain list b

Pagina 27 - VC Domains 27

DescriptionIconStatusFailed to connect to the VC Domain. Possiblecauses include:• Connection times out.• Ethernet VC Module is physically notavailable

Pagina 28 - 28 Managing VC Domains

• MAC or WWN addresses or serial numbers that are assigned to a profile must not be in use by VCEMor in a VCEM exclusion list. If the MAC or WWN addre

Pagina 29 - VC Domains 29

• Server VLAN Tagging support:Tunnel VLAN Taggings or Map VLAN Taggings•• Force Server connection setting• Multiple Network Speeding Settings:Preferre

Pagina 30 - VC Domain tasks

• Native• Smart Link• Private network• Preferred Link Connection• Preferred Link Connection Speed• Maximum Link Connection• Maximum Link Connection Sp

Pagina 31 - Creating a VC Domain Group

Virtual Connect 2.3x features that must be disabled in a VC Domain to be part of the VC DomainGroup with Virtual Connect firmware 2.1xIMPORTANT: If yo

Pagina 32 - 32 Managing VC Domains

d. To disable trap severities, from the Add a SNMP Trap Destination page, click Advanced, asshown in the following figure.Figure 3-4 Disabling trap se

Pagina 33 - VC Domains 33

Figure 3-6 Disabling Virtual Connect Manager traps3. Do not modify the SNMP configuration for VC Domain level. The default SNMP configuration forVC Do

Pagina 34 - 34 Managing VC Domains

Figure 3-8 Multienclosure VC Domain• The HP Virtual Connect 8Gb 24-Port FC Module is not supported.Do not insert the HP Virtual Connect 8Gb 24-Port FC

Pagina 35 - VC Domains 35

Table of ContentsAbout this document...9Intended audience...

Pagina 36 - VC Domain Maintenance

Figure 3-10 Fibre Channel port speed set to 8GbVC Domain tasksFrom the VC Domains page, you can perform the following tasks:• License an enclosure for

Pagina 37 - VC Domains 37

Creating a VC Domain GroupYou can create a VC Domain Group by selecting the VC Domains that you want to incorporate into a newVC Domain Group.IMPORTAN

Pagina 38 - 38 Managing VC Domains

4. Enter the VC Domain Group name in the VC Domain Group Name field. Valid VC Domain Groupnames are alphanumeric, hyphens (-), underscore (_), and can

Pagina 39 - VC Domains 39

• If HP Virtual Connect 8Gb 24-port FC modules and HP Virtual Connect 4Gb FC modules share thesame IO bay slice. (For example, a HP Virtual Connect 4G

Pagina 40 - 40 Managing VC Domains

deleting the VC Domain Group or removing the VC Domain from a VC Domain Group. HP recommendsthat you provide MAC, WWN, and serial number ranges that a

Pagina 41 - VC Domains 41

The following figure illustrates a valid configuration of Ethernet and Fibre Channel Virtual Connect modulesin a VC Domain with multiple enclosures. T

Pagina 42 - 42 Managing VC Domains

Figure 3-12 VC Domain Group with VC Domains that have different numbers of enclosuresA multienclosure domain can only be configured as follows:• The e

Pagina 43 - 4 Managing VC Domain Groups

automatically to all other VC Domains that belong to the same VC Domain Group. VCEM accomplishes thistask by temporarily enabling domain, network, and

Pagina 44

VC Domain Group configuration replicated to other VC Domains during VC Domain MaintenanceIMPORTANT: The VC Domain, network, and storage configuration

Pagina 45 - VC Domain Groups 45

• Connection mode• Smart link• Private network• Enable VLAN tunneling• States• Network port location• Speed/duplex mode• Connection mode• Preferred li

Pagina 46 - Deleting a VC Domain Group

4 Managing VC Domain Groups...43VC Domain Groups...

Pagina 47 - VC Domain Groups 47

IMPORTANT: When a VC Domain is put in VC Domain Maintenance, operations such as backup andrestore Virtual Connect configurations are allowed. Restorin

Pagina 48 - 48 Managing VC Domain Groups

IMPORTANT: The domain configuration backup file created during VC Domain Maintenance and is validfor restoration while the VC Domain is in VC Domain G

Pagina 49 - VC Domain Groups 49

IMPORTANT: For more information on the domain, network, and storage configurations that VCEM canreplicate during completion of VC Domain Maintenance,

Pagina 50

4 Managing VC Domain GroupsVC Domain GroupsThis section describes the management of Virtual Connect (VC) Domain Groups using VCEM.A VC Domain consists

Pagina 51 - 5 Managing server profiles

DescriptionIconStatusVC Domain is unlocked for domain, network,and storage changes through the VirtualConnect Manager. After completing thedomain netw

Pagina 52 - 52 Managing server profiles

3. Enter the username and password for each VC Domain. Ensure you provide VC Domain credentialswill full privileges. VC Domains appear as:• Unconfigur

Pagina 53 - Creating a profile

1. Select the VC Domain Group on which you want to perform maintenance.2. Click VC Domain Maintenance.3. Select the target VC Domain within the select

Pagina 54 - Configuring multiple networks

completed, look at the report generated by the related job in the VCEM event. To access this report fromthe HP SIM left navigation panel, select Event

Pagina 55 - Profiles 55

4. Perform the following actions for each VC Domain that uses HP-predefined or user-defined ranges withinthe VC Domain Group that you want to remove.

Pagina 56 - Editing a profile

3. For each VC Domain released from the VC Domain Group, insert or remove VC modules in thecorresponding enclosure, and perform the necessary domain,

Pagina 57 - Unassigning a profile

Deleting WWN exclusion ranges...71Allocating WWN a

Pagina 59 - Designating spare bays

5 Managing server profilesProfilesThis section describes how to create and manage profiles for use with VCEM.A Virtual Connect server profile is a log

Pagina 60 - HP SIM User Guide

A server profile defines connections for a blade server. Server profiles can include the following information:• Profile name• Logical serial number a

Pagina 61 - 6 Managing bays

power off the server blade to perform server profile operations with VC firmware 2.0x or 2.1x. However,in VC firmware 2.3x, you can perform these oper

Pagina 62 - Powering down a bay

Target boot LUN values must be compliant with proper ranges.▲ VC Domains—You can provide the target boot LUN in either of the possible formats:When us

Pagina 63 - Assigning a profile to a bay

Figure 5-3 Copying a profile using the Copy from button5. (Optional) You can create vNet mappings based on a shared uplink set. To perform this task,

Pagina 64

Deleting a profileVCEM detects the presence of logical server managers or upper level managers. When performing this task,a prompt dialog message appe

Pagina 65

1. From the Profiles page, select the profile to be verified.2. Click Edit. The Edit Profile information appears below the profile table.3. In the Pro

Pagina 66

7. Click OK. The Virtual Connect Enterprise Manager is executing the request messageappears.8. Click OK to go to the Jobs page and monitor job progres

Pagina 67 - MAC Addresses

Preconditions for VC Profile Failover• Source and designated spare servers must be part of the same VC Domain.• Designated spare servers are powered o

Pagina 68 - Deleting MAC exclusion ranges

Cannot change the MAC/WWN/Serial Number ranges in Virtual Connect Manager when there are serverprofiles...

Pagina 69 - WWN Addresses

1. Enable HP SIM automatic discovery by selecting Options→Discovery. Discovery must be enabled todiscover servers within the environment.2. Enable act

Pagina 70 - Creating WWN exclusion ranges

6 Managing baysBaysOnly the bays that are inside a VC Domain Group appear on the Bays page.Bays can be filtered by selecting one of the following entr

Pagina 71 - Allocating WWN addresses

DescriptionItemModel of blade serverBlade modelEnclosure is powered-up or powered-downPowerUnique identifier that tells if the light on the device is

Pagina 72

1. Click the Bays tab.2. To determine the power status of the bay, click the bay number. A status window appears.3. Depending on the power status of t

Pagina 73 - WWN Addresses 73

1. Click the Bays tab.2. (Optional) From the Filter list, select VC Domain or VC Domain Group.3. Select the bay for which you want to unassign a profi

Pagina 74

Preconditions for VC Profile Failover• Source and designated spare servers must be part of the same VC Domain.• Designated spare servers are powered o

Pagina 75 - Logical Serial Numbers

1. Enable HP SIM automatic discovery by selecting Options→Discovery. Discovery must be enabled todiscover servers within the environment.2. Enable act

Pagina 76

7 Managing MAC and WWN addressesThis section describes how to manage MAC and WWN addresses using VCEM.MAC AddressesNOTE: A "VCEM-defined” range h

Pagina 77 - 9 Tracking VCEM job status

DescriptionItemAddress available to use in VCEM.FreeAddress currently used by a server profile in VCEM.In useAddresses used by server profiles in a VC

Pagina 78 - Deleting jobs

5. From the Filter list, select External.6. Select the external addresses to be reclaimed.7. Click Reclaim External. You are prompted to confirm your

Pagina 79 - Preparation checklist

List of Figures1-1 HP Virtual Connect technology...

Pagina 80

user-defined WWNs. You can use the HP-predefined range only for import profiles or profiles created onprevious versions of VCEM.To access WWN addresse

Pagina 81

3. Select a WWN address range. The exclusion range must be contained within the address range towhich the exclusion range belongs.4. Select the Exclus

Pagina 82

Figure 7-3 WWN Ranges List page3. Select a WWN address range. The exclusion range must be contained within the address range towhich the exclusion ran

Pagina 83

To add WWN custom address ranges:1. From the Virtual Connect Enterprise Manager home page, under the Administration heading, click theWorld Wide Names

Pagina 85 - CLI exit and error codes

8 Working with Logical Serial NumbersLogical Serial NumbersThis section describes how to view logical serial numbers that exist in server profiles bei

Pagina 87 - 13 Troubleshooting VCEM

9 Tracking VCEM job statusJobsThe Jobs list provides detailed information about jobs that have occurred and are related to VCEM. To viewthese jobs, cl

Pagina 88 - 88 Troubleshooting VCEM

VCEM limits the number of jobs that it displays to 65,000. If the limit is reached, then only the most recent65,000 jobs are viewable. To keep the lis

Pagina 89 - Troubleshooting 89

10 Upgrading Virtual Connect firmware after VCEM ismanaging VC DomainsThe process for upgrading Virtual Connect (VC) firmware requires extra steps whe

Pagina 92 - 92 Troubleshooting VCEM

11 Removing an external manager accountFor VCEM to manage VC Domains (using the Virtual Connect Manager, the embedded software in a VirtualConnect Eth

Pagina 94 - Backing up and restoring VCEM

12 Command Line Interface usage in VCEMVCEM provides support for a command line interface (CLI) to perform several failover-related functions. Thesesa

Pagina 95 - Troubleshooting 95

>vcem –list –details –job JobNumberIf the CLI List Job Details command is successful, the exit code from the CLI is zero, and the followingexample

Pagina 96 - 96 Troubleshooting VCEM

CLI exit and error codesThe CLI returns a numeric value that either indicates success or a particular error or failure. The CLI alsodisplays an associ

Pagina 98 - 98 Troubleshooting VCEM

13 Troubleshooting VCEMTroubleshootingIMPORTANT: VCEM 6.0 supports the Microsoft Internet Explorer 8 (IE8) browser, but the underlying VirtualConnect

Pagina 99 - Troubleshooting 99

The HP Virtual Connect has lost its login credentials for the HP Onboardadministrator (OA). The OA may have been replaced or reset to factory defaults

Pagina 100 - 100 Troubleshooting VCEM

Cannot access VC Domain from Virtual Connect Manager after a data migration hasbeen performedIf, after performing data migration, you are running Virt

Pagina 101 - Troubleshooting 101

About this documentIntended audienceThis document is intended to be used by technical professionals who manage multiple HP BladeSystemenclosures and u

Pagina 102 - 102 Troubleshooting VCEM

VC Domain displays Configuration Mismatch statusIf the VCEM data does not match the data from the VC Domain, then the Configuration Mismatch iconappea

Pagina 103 - HP contact information

If VC Domain firmware is 2.0x or later, perform the following:• To remove the account and release the VC Domain from VCEM control, from the Virtual Co

Pagina 104

1. Click the VC Domains or VC Domain Groups tab.a. Select the VC Domain or VC Domain Groupb. Click VC Domain Maintenance.c. Click Complete VC Domain M

Pagina 105 - Glossary

Error on database operation occursErrors might occur during database operations if:• VCEM tables are missing; that is, Database Administrator deleted

Pagina 106 - See also

Creating a server profile or adding a VC Domain to a VC Domain Group failsAttempting to create a profile or adding a VC Domain to a VC Domain Group mi

Pagina 107

Figure 13-1 Backing up and restoring VCEMThe Domain Network and SAN Configuration and assigned Server Profiles can be recovered from the VirtualConnec

Pagina 108

1. To remove the account and release the VC Domain from VCEM control, from the Virtual Connect Managercommand prompt, enterremove external-manager Use

Pagina 109

4. Replace the VC modules from the enclosure reader interconnect bays. Verify that the network and SANconnections that are wired to the new VC modules

Pagina 110 - 110 Index

Error during Edit server profile [Profile Name]. Details: This action couldnot be performed because the server is powered on. Power down the serverass

Pagina 111

As a result, VCEM might display false job results such as, "Completed with success," even though the serverprofile changes have not taken ef

Comentarios a estos manuales