7 Internal mappings and cabling
recommendations
When attaching storage enclosures to SAS ports on the HP 3G SAS BL Switch, use the following
cabling guidelines.
c3000 recommendations
Table 1 Half-height server blades in c3000 device bays
Install 3Gb SAS BL Switches in c3000 interconnect bays 3 and
4
Attach storage enclosures for these servers to ports 14 of the
3Gb SAS BL Switches
Install the P700m SAS controller in
mezzanine slot 2 (mezzanine slot 1 is
not supported)
nl
nl
Table 2 BL2x220c server blades in c3000 device bays 18
Install 3Gb SAS BL Switches in c3000 interconnect bays 3 and
4
Attach storage enclosures for these servers to ports 14 of the
3Gb SAS BL Switches
A servers
Install 3Gb SAS BL Switches in c3000 interconnect bays 3 and
4
Attach storage enclosures for these servers to ports 58 of the
3Gb SAS BL Switches
B servers
nl
nl
Table 3 Full-height server blades in c3000 device bays
Install 3Gb SAS BL Switches in c3000 interconnect bays 3 and
4
Attach storage enclosures for these servers to ports 14 of the
3Gb SAS BL Switches
If the P700m SAS controller is installed
in mezzanine slot 2:
Install 3Gb SAS BL Switches in c3000 interconnect bays 3 and
4
Attach storage enclosures for these servers to ports 58 of the
3Gb SAS BL Switches
If the P700m SAS controller is installed
in mezzanine slot 3:
nl
nl