Class keys/properties
CommentsDescriptionProperty Name
The CreationClassName of the
scoping system.
HPSVSP_StorageAppliance"SystemCreationClassName
The Name of the scoping Sys-
tem.
Same as
HPSVSP_StorageAppliance.Name.
SystemName
The name of the class used in
the creation of this instance.
HPSVSP_DPMBackSideFCPortCreationClassName
The unique DeviceID key for the
HPSVSP_DPMFCPort manufac-
tured from the SVSP domain of
the active VSM that views the
DPM, the DPM on which the
port is located, and the port
number itself
DeviceID
This property is defined to con-
tain the Port Symbolic Name.
ElementName
The port's mode of use allowed
by the implementation (front-
end, back-end, or norestriction).
Set to 3 ("Back-end only")UsageRestriction
The status of the port.
{ 2 ("OK") }
OperationalStatus[]
NULLHealthState
The specific mode to which the
port is set.
0 "Unknown"
1 "Other"
10 "N" Node Port
11 "NL" Node Port supporting FC arbit-
rated loop
14 "E" Expansion Port connecting fabric
elements (for example, FC switches)
15 "F" Fabric (element) Port
16 "FL" Fabric (element) Port supporting
FC arbitrated loop
PortType
Speed in bits per second. Shall
be:
0, 1062500000 (1GFC)
2125000000 (2GFC)
4250000000 (4GFC)
8500000000 (8GFC)
10518750000 (10GFC)
14025000000 (16GFC)
21037500000 (20GFC),
or
28500000000 (32GFC)
SpeedSpeed