Hp XP Continuous Access Software Manual de usuario Pagina 116

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 412
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 115
116 HP StorageWorks Disk Array XP RAID Manager: User’s Guide
–t timeout (Asynchronous paired volumes only) Specifies the
maximum time in seconds to wait for a
resynchronization of P-VOL to S-VOL delta data. If the
timeout occurs,
EX_EWSTOT is returned. This option
is required for an asynchronous paired volume; it has
no effect for a synchronous paired volumes.
–z Makes this command enter interactive mode.
–zx (Not for use with MPE/iX or OpenVMS) Prevents using
RM in interactive mode.
Returned Values The horctakeover command returns one of the following values in exit().
Normal termination
0: nop-takeover (no operation)
1: swap-takeover was successfully executed
2: SVOL-takeover was successfully executed
3: PVOL-SMPL-takeover was successfully executed
4: PVOL-PSUE-takeover was successfully executed
5: SVOL-SSUS-takeover was successfully executed
(This returned value depends on the microcode level.)
Abnormal termination
Other than the above. For the error cause and details, see the execution
logs.
Execution Log File After the SVOL-takeover is executed, if inconsistent volumes exist, they
are displayed in the execution log file.
Vista de pagina 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 411 412

Comentarios a estos manuales

Sin comentarios