Hp Insight Management-Software Manual de usuario Pagina 137

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 152
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 136
VC Domain status is "Mismatch Configuration" after cancel a VC Domain
Maintenance operation fails
This situation occurs when the server profiles from a VC Domain managed by VCEM have changed
and do not match the existing server profiles in the VCEM database. For example, restoring an
old VC Domain backup that has a different server profile from the current VC Domain in the VCEM
database.
In such cases, VCEM changes the VC Domain status to "Mismatch Configuration," and the VC
Domain Group to, "Configuration in sync." To continue managing this VC Domain with VCEM,
click VC Domain Maintenance to resynchronize the VC Domain configuration and server profiles.
Server profile job completed successfully but changes have not occurred
If a VC Domain is managed by VCEM, and Onboard Administrator is brought out of Virtual Connect
Mode, the following error message appears the next time you log in to Virtual Connect Manager:
The HP Virtual Connect has lost its login credentials for the HP Onboard
Administrator (OA). OA may have been replaced or reset to factory
defaults. To ensure proper operation, these credentials must be
reestablished.
When the Onboard Administrator credentials are provided, an error message appears stating that
the credentials are not valid. This situation can occur when:
Onboard Administrator is replaced or reset to factory default settings.
The clear vcmmode command was executed in the Onboard Administrator command line
interface.
The VC Ethernet modules were temporarily replaced by another BladeSystem c-Class
interconnect module.
As a result, VCEM might display incorrect job results such as, "Completed with success," even
though the server profile changes have not taken effect. The ability of VCEM to manage server
profiles might also be affected for:
Creating an unassigned server profile
Editing of an assigned server profile
Assigning a server profile
Deleting a server profile
Unassigning a server profile
The following bay operations might also be affected:
Incorrect information might be displayed for power status, the server model, and serial number
Power buttons might not perform the expected operations
In addition, after logging in to the Virtual Connect Manager user interface, the following warning
message might appear:
The HP Virtual Connect has lost its login credentials for HP Onboard
Administrator (OA). OA may have been replaced or reset to factory
defaults. To ensure proper operation, these credentials must be
reestablished.
This situation occurs because VCEM relies on proper communication from the Virtual Connect
Manager to the Onboard Administrator to retrieve and change configurations, statuses of the
physical devices inside the enclosure, and perform server power all on and off operations.
To correct this issue, restore communication between the Onboard Administrator and Virtual
Connect Manager by performing the following:
VC Domain status is "Mismatch Configuration" after cancel a VC Domain Maintenance operation fails 137
Vista de pagina 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 151 152