【Enter Setup】
**【Exit Setup】 94
Set Length Range for MSI-Plessey
The scanner can be c onfigured t o o nly de code MSI-Plessey bar codes with lengths that f all between ( inclusive) t he
minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.
【Set the Minimum Length (Default: 4)】
【Set the Maximum Length (Default: 48)】
If minimum length is set to be greater than maximum length, the scanner only decodes MSI-Plessey bar
codes with either the minimum or maximum length. If minimum length is same as maximum length, only
MSI-Plessey bar codes with that length are to be decoded.
To set the scanner to decode MSI-Plessey bar codes containing between 8 and 12 characters:
1. Scan the Enter Setup bar code.
2. Scan the Set the Minimum Length bar code.
3. Scan the numeric bar code “8”. (See the “Digit Bar Codes” section in Appendix)
4. Scan the Save bar code. (See the “Save/Cancel Bar Codes” section in Appendix)
5. Scan the Set the Maximum Length bar code.
6. Scan the numeric bar code “1”.
7. Scan the numeric bar code “2”.
8. Scan the Save bar code.
9. Scan the Exit Setup bar code.