【Enter Setup】
3 **【Exit Setup】
Good Read Beep Duration
The Good Read Beep Duration codes modify the length of the beep that the scanner emits on a good read.
Default = Medium.
**【Medium】
【Short】
【Custom (20-300ms)】
To set the Good Read Beep Duration to 50ms:
1. Scan the Enter Setup bar code.
2. Scan the Custom (20-300ms) bar code.
3. Scan the Digit Codes “5” and “0”. (See the “Digit Bar Codes” in Appendix)
4. Scan the Save bar code. (See the “Save/Cancel Bar Codes” in Appendix)
5. Scan the Exit Setup bar code.