Cabling the Fibre Channel Converter
9800FC (CT9800FC) Fibre Channel Converter Installation and User’s Guide—524957-003
3-3
Installing the SCSI Interface Cable
Installing the SCSI Interface Cable
1. Before you install the 68-pin SCSI cable from the Fibre Channel converter to the
server, check that the tape drive and the Fibre Channel converter are both
powered off. Refer to Appendix A, Multimode Fiber Optic Cables for cable part
numbers.
2. Connect the 68-pin SCSI cable to the SCSI channel port on the Fibre Channel
converter.
3. Connect the other end of the 68-pin SCSI cable to a supported SCSI port on a
NonStop S-series server. For example, see Figure 3-3 for the ServerNet/DA.
Table 3-1. Connections Supported for the Fibre Channel Converter
Server ServerNet/DA IOMF CRU IOMF 2 CRU PMF CRU
S7000 Yes No No No
S7400 Yes No Yes No
S70000 Yes No Yes No
S72000 Yes No Yes No
S74000 Yes No Yes Yes
S76000 Yes No Yes Yes
S86000 Yes No Yes Yes