Installing and Configuring the 9840FC Tape Drive for
the NonStop NS-Series Server
9840 (CT9840FC-3) Installation and User’s Guide for the NonStop S-Series Enclosure524959-003
D-4
Installation
2. Connect the other end of the fiber cable to the Fibre Channel ServerNet adapter
(FCSA) on the NonStop NS-series server. For the location, see Figure D-5 on
page D-6.
A SC-LC fiber-optic cable must be used to connect the tape drive to the FCSA.
The SC side of the cable connects to the tape drive, and the LC side connects to
the FCSA. Figure D-4 on page D-5 shows each side of the cable.
Figure D-3. Close-Up View of Fibre Channel Connectors
Table D-1. Fiber Cables
Connector Fiber Cable Fiber Cable Distance
SC - LC 50/125 µm 2-500 meters (6.56-1640.42 feet)
SC - LC 62.5/125 µm 3-300 meters (9.84-984.25 feet)
Port A