Switch Command Interface (SWCI)
ServerNet Nomadic Disk (Release 2) User’s Guide523968-001
6-42
Switch Protocol Error Messages
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. The FRU tracking code field of an SCC or switch card FIR string read from the
switch module is not present or is incorrectly specified.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. The FRU tracking code field header of an SCC or switch card FIR string read
from the switch module is incorrectly specified.
Effect. SWCI does not work properly.
Recovery. Do the following:
1. Check the configuration of the switch module device and reconfigure if necessary.
2. Check the version of SWCI installed.
3. Power the switch module device off then back on again.
Cause. The protocol revision field of an SCC FIR string read from the switch module is
not present or is incorrectly specified.
Effect. SWCI does not work properly.
***PROTOCOL ERROR*** Bad tracking code field in SCC/SC FIR
string.
***PROTOCOL ERROR*** Bad tracking code header in SCC/SC FIR
string.
***PROTOCOL ERROR*** Bad protocol revision field in SCC FIR
string.”