Hp ProLiant BL490c G7 Server-Blade Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware De La Computadora Hp ProLiant BL490c G7 Server-Blade. HP ProLiant BL490c G7 Server-Blade User Manual [fr] [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 94
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
HP ProLiant BL490c G7 Server Blade
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 613023-002
March 2011
Edition: 2
Vista de pagina 0
1 2 3 4 5 6 ... 93 94

Indice de contenidos

Pagina 1 - User Guide

HP ProLiant BL490c G7 Server Blade User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and stor

Pagina 2

Component identification 10 HP c-Class Blade SUV Cable Item Connector Description 1 Server blade For connecting to the SUV connector on the s

Pagina 3 - Contents

Operations 11 Operations Power up the server blade The HP BladeSystem Onboard Administrator initiates an automatic power-up sequence when the server

Pagina 4 - Contents 4

Operations 12 • Use the HP BladeSystem Onboard Administrator GUI to initiate a shutdown: a. Select the Enclosure Information tab, and then select

Pagina 5 - Contents 5

Operations 13 Remove the access panel To remove the component: 1. Power down the server blade (on page 11). 2. Remove the server blade (on page 12

Pagina 6 - Component identification

Setup 14 Setup Overview To install a server blade, complete the following steps: 1. Install and configure an HP BladeSystem c-Class enclosure. 2.

Pagina 7 - System board components

Setup 15 Interconnect bay numbering and device mapping • HP BladeSystem c7000 Enclosure To support network connections for specific signals, insta

Pagina 8 - System maintenance switch

Setup 16 • HP BladeSystem c3000 Enclosure and Tower Enclosure Server blade signal Interconnect bay number Interconnect bay label Notes Flex a

Pagina 9 - Accessing the redundant ROM

Setup 17 Connecting to the network To connect the HP BladeSystem to a network, each enclosure must be configured with network interconnect devices t

Pagina 10 - HP c-Class Blade SUV Cable

Setup 18 2. Remove the enclosure connector cover. 3. Prepare the server blade for installation.

Pagina 11 - Operations

Setup 19 4. Install the server blade. Completing the configuration To complete the server blade and HP BladeSystem configuration, see the overvie

Pagina 12 - Remove the server blade

© Copyright 2010, 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Pagina 13 - Install the access panel

Hardware options installation 20 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Pagina 14 - Overview

Hardware options installation 21 5. Install the hard drive. 6. Connect and route the cables. 7. Install the access panel (on page 13). 8. Inst

Pagina 15

Hardware options installation 22 • Single- and dual-rank PC3-10600 (DDR-1333) DIMMs operating at 1333 and 1066 MHz • Quad-rank PC3-8500 (DDR-1067)

Pagina 16

Hardware options installation 23 The memory subsystem may be populated with either RDIMMs or UDIMMs, but mixing the two types is not supported. To d

Pagina 17 - Installing a server blade

Hardware options installation 24 For the latest memory configuration information, see the QuickSpecs on the HP website (http://www.hp.com). RDIMM m

Pagina 18 - Setup 18

Hardware options installation 25 General DIMM slot population guidelines Observe the following guidelines for all AMP modes: • Populate DIMM slots

Pagina 19 - Completing the configuration

Hardware options installation 26 • Always install DIMMs in channels 1 and 2 for each installed processor. • Do not install DIMMs in channel 3 for

Pagina 20 - Hard drive option

Hardware options installation 27 • Observe the general DIMM slot population guidelines (on page 25). • Always install DIMMs in channels 1 and 2 fo

Pagina 21 - Memory options

Hardware options installation 28 WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system compon

Pagina 22 - DIMM identification

Hardware options installation 29 7. Install the DIMM. 8. Install the DIMM baffle. 9. Connect the hard drive cables. 10. Install the access pane

Pagina 23 - Memory configurations

Contents 3 Contents Component identification ...

Pagina 24

Hardware options installation 30 5. Disconnect the hard drive cables from the system board. 6. Remove the DIMM baffle with the hard drives and ca

Pagina 25

Hardware options installation 31 7. Open the processor locking lever and the processor socket retaining bracket. Do not remove the processor socket

Pagina 26

Hardware options installation 32 9. Align the processor installation tool with the socket, and then install the processor. THE PINS ON THE SYSTEM B

Pagina 27 - Installing DIMMs

Hardware options installation 33 10. Press the tabs on the processor installation tool to separate it from the processor, and then remove the tool.

Pagina 28

Hardware options installation 34 12. Remove the thermal interface media protective cover. CAUTION: To avoid damage to the system board, proce

Pagina 29 - Processor option

Hardware options installation 35 Mezzanine card option Optional mezzanine cards are classified as Type I mezzanine cards and Type II mezzanine cards

Pagina 30

Hardware options installation 36 5. Install the mezzanine card. Press down on the connector to seat the board. 6. Install the access panel (on pa

Pagina 31

Hardware options installation 37 • Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon l

Pagina 32

Hardware options installation 38 6. Install the TPM security rivet by pressing the rivet firmly into the system board. 7. Install the access pane

Pagina 33

Hardware options installation 39 CAUTION: When a TPM is installed and enabled on the server blade, data access is locked if you fail to follow th

Pagina 34

Contents 4 Accessing a server blade with local media devices ... 41 Softwar

Pagina 35 - Mezzanine card option

Cabling 40 Cabling Hard drive cabling CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinch

Pagina 36

Cabling 41 Numerous configurations are possible. This section offers two possible configurations. For more information, see "USB support and fu

Pagina 37

Cabling 42 3. Connect a USB hub to one USB connector. 4. Connect the following to the USB hub: o USB CD/DVD-ROM drive o USB keyboard o USB mous

Pagina 38

Software and configuration utilities 43 Software and configuration utilities Server blade deployment tools HP BladeSystem c-Class Advanced managemen

Pagina 39

Software and configuration utilities 44 Deployment overview When a PXE-enabled target server blade boots, it obtains an IP address from a DHCP serve

Pagina 40 - Cabling

Software and configuration utilities 45 o 64 MB of RAM o 64 MB of free hard drive space o 1-Gb/s network adapter or greater • PXE deployment ser

Pagina 41

Software and configuration utilities 46 PXE deployment PXE enables server blades to load an image over the network from a PXE server, and then execu

Pagina 42

Software and configuration utilities 47 • USB CD-ROM (on page 47) iLO virtual CD-ROM To deploy with a boot CD: 1. Do one of the following: o Ins

Pagina 43 - Network-based PXE deployment

Software and configuration utilities 48 Creating a boot diskette The SmartStart Scripting Toolkit provides the tools and information for creating a

Pagina 44 - Deployment infrastructure

Software and configuration utilities 49 For SAN configuration information for the server blade, refer to the HP StorageWorks SAN Design Reference Gu

Pagina 45 - Deployment methods

Contents 5 Battery replacement ...

Pagina 46 - CD-ROM deployment

Software and configuration utilities 50 • Selecting the primary boot controller • Configuring memory options • Language selection For more inform

Pagina 47 - Diskette image deployment

Software and configuration utilities 51 For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the H

Pagina 48 - SAN configuration

Software and configuration utilities 52 7. Press the Esc key to exit the current menu or press the F10 key to exit RBSU. For more information on mi

Pagina 49 - Configuration tools

Software and configuration utilities 53 The utility also provides support for the following functions: • Reconfiguring one or more logical drives •

Pagina 50 - Auto-configuration process

Software and configuration utilities 54 ASR increases server availability by restarting the server within a specified time after a system hang or sh

Pagina 51 - Configuring mirrored memory

Software and configuration utilities 55 CAUTION: Perform a backup before running the System Erase Utility. The utility sets the system to its orig

Pagina 52 - Array Configuration Utility

Software and configuration utilities 56 Internal USB functionality An internal USB connector is available for use with security key devices and USB

Pagina 53 - Management tools

Software and configuration utilities 57 Integrated Management Log The IML records hundreds of events and stores them in an easy-to-view form. The I

Pagina 54 - Erase Utility

Software and configuration utilities 58 Keeping the system current Drivers IMPORTANT: Always perform a backup before installing or updating devi

Pagina 55 - Redundant ROM support

Software and configuration utilities 59 • Offline, automatic mode for HP ProLiant BL, DL, ML, and 100 Series servers • Firmware deployment support

Pagina 56 - Diagnostic tools

Component identification 6 Component identification Front panel components Item Description 1 HP c-Class Blade SUV Cable connector 2 Serial la

Pagina 57 - Integrated Management Log

Troubleshooting 60 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common

Pagina 58 - Keeping the system current

Troubleshooting 61 Important safety information Before servicing this product, read the Important Safety Information document provided with the s

Pagina 59 - Care Pack

Troubleshooting 62 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling feet are extended to t

Pagina 60 - Troubleshooting

Troubleshooting 63 o HP recommends you have access to the server documentation for server-specific information. o HP recommends you have access to

Pagina 61 - Warnings

Troubleshooting 64 Always use the recommended minimum configuration above before removing any processors. If you are unable to isolate the issue wit

Pagina 62 - Symptom information

Troubleshooting 65 do not provide a troubleshooting solution, follow the diagnostic steps in "General diagnosis flowchart (on page 66)." T

Pagina 63 - Troubleshooting 63

Troubleshooting 66 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure

Pagina 64 - Troubleshooting flowcharts

Troubleshooting 67 Item See 4 The most recent version of a particular server blade or option firmware is available on the HP Support website (http:

Pagina 65 - Start diagnosis flowchart

Troubleshooting 68 Server blade power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.

Pagina 66 - General diagnosis flowchart

Troubleshooting 69 • The health LED is red or amber. NOTE: For the location of server LEDs and information on their statuses, refer to the ser

Pagina 67

Component identification 7 Item Description Status 2 Internal health LED Green = Normal Flashing = Booting Amber = Degraded condition Red = Criti

Pagina 68 - Symptoms:

Troubleshooting 70 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system att

Pagina 69

Troubleshooting 71 Item See 1 Server blade power-on problems flowchart (on page 68) 2 "POST error messages and beep codes (on page 76)&quo

Pagina 70 - POST problems flowchart

Troubleshooting 72 OS boot problems flowchart There are two ways to use SmartStart when diagnosing OS boot problems on a server blade: • Use iL

Pagina 71

Troubleshooting 73 Possible causes: • Corrupted OS • Hard drive subsystem problem • Incorrect boot order setting in RBSU Item See 1 HP ROM-B

Pagina 72 - OS boot problems flowchart

Troubleshooting 74 * See the server blade OS boot problems flowchart (on page 72) Server fault indications flowchart Symptoms: • Server boots, bu

Pagina 73 - • Corrupted OS

Troubleshooting 75 NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation. Possible causes:

Pagina 74

Troubleshooting 76 POST error messages and beep codes For a complete listing of error messages, refer to the "POST error messages" in th

Pagina 75 - • Redundancy failure

Troubleshooting 77 WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before re

Pagina 76 - (http://www.hp.com/support)

Battery replacement 78 Battery replacement If the server blade no longer automatically displays the correct date and time, you may need to replace t

Pagina 77 - Troubleshooting 77

Regulatory compliance notices 79 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Pagina 78 - Battery replacement

Component identification 8 Item Description 13 TPM connector 14 System maintenance switch 15 Processor socket 2 16 Processor socket 1 The symbols

Pagina 79 - Class B equipment

Regulatory compliance notices 80 radio communications. However, there is no guarantee that interference will not occur in a particular installation.

Pagina 80 - Modifications

Regulatory compliance notices 81 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. C

Pagina 81 - • EMC Directive 2004/108/EC

Regulatory compliance notices 82 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other

Pagina 82 - Korean notice

Regulatory compliance notices 83 Class B equipment Chinese notice Class A equipment Laser compliance This product may be provided with an optica

Pagina 83 - Battery replacement notice

Regulatory compliance notices 84 For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized

Pagina 84

Electrostatic discharge 85 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Pagina 85 - Electrostatic discharge

Specifications 86 Specifications Environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°F) Non-

Pagina 86 - Specifications

Technical support 87 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical su

Pagina 87 - Technical support

Technical support 88 • An HP support specialist will diagnose and assess whether a replacement part is required to address a system problem. The sp

Pagina 88 - Technical support 88

Acronyms and abbreviations 89 Acronyms and abbreviations ABEND abnormal end AMP Advanced Memory Protection ASR Automatic Server Recovery CSR Cust

Pagina 89 - Acronyms and abbreviations

Component identification 9 5. Install the access panel (on page 13). 6. Install the server blade in the enclosure and power up the server blade. 7

Pagina 90

Acronyms and abbreviations 90 PSP ProLiant Support Pack PXE Preboot Execution Environment RBSU ROM-Based Setup Utility SUV serial, USB, video TF

Pagina 91 - Index 91

Index 91 A access panel 14 accessing a server blade with local KVM 44 acoustics statement for Germany 91 ACU (Array Configuration Utility) 5

Pagina 92 - Index 92

Index 92 F FCC (Federal Communications Commission) notice 85, 86, 87 FCC rating label 85 features 6 Federal Communications Commission (FCC) no

Pagina 93 - Index 93

Index 93 multi-processor Lockstep population order 30 multi-processor Mirrored Memory population order 29 N network connections 18 network-bas

Pagina 94 - Index 94

Index 94 support packs 52 supported operating systems 63 supported servers 65 supported targets 65 switches, interconnect 15 symbols on eq

Comentarios a estos manuales