Hardware options installation 61
13.
Install the access panel (on page 20).
14. Slide the server into the rack.
15. Power up the server (on page 18).
Using a PCI array controller and the HP Smart Array P400i
Controller to support six hard drives
1. Power down the server (on page 18).
2. Extend the server from the rack (on page 19).
3. Remove the access panel (on page 20).
4. Remove the air baffle ("Remove and install the air baffle" on page 20).
5. Remove fan modules 1 and 2 ("Remove and install a fan module" on page 23).
6. Route and connect the data cables:
o Connect the PCI SAS or SATA array controller to the SAS hard drive backplane.
o Connect the HP Smart Array P400i Controller to the SAS hard drive backplane.
CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure
the cables do not interfere with fan module installation. Be sure to route the cables around the
access panel mounting pin bracket so as not to interfere with access panel installation.
CAUTION: When routing cables, always be sure that the cables are not in a position where
they can be pinched or crimped.
7. Install fan modules 1 and 2 ("Remove and install a fan module" on page 23).
8. Install the air baffle ("Remove and install the air baffle" on page 20).
9. Install the access panel (on page 20).
10. Slide the server into the rack.
11. Power up the server (on page 18).