Hp ProLiant DL585 Server Manual de usuario Pagina 66

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 183
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 65
Installing hardware options
HP ProLiant DL585 Server User Guide 4-15
Determining the proper hot-plug SCSI hard drive installation order
The system reads and manages the hot-plug SCSI hard drives based on the SCSI ID
number assigned to each drive. For optimal hard drive management and performance,
install the hard drives in the order of SCSI ID assignments. Always populate hard
drive bays starting with the lowest SCSI ID.
Figure 4-13: Hot-plug SCSI hard drives and SCSI ID
numbers
Table 4-5: Hot-plug SCSI hard drives and SCSI ID numbers
Item Description Simplex SCSI ID Duplex SCSI ID
1 SCSI hard drive 1 0 0
2 SCSI hard drive 2 1 1
3 SCSI hard drive 3 2 0
4 SCSI hard drive 4 3 1
Note: Simplex configuration equals all four drives in the server connected to
one SCSI channel. Duplex configuration equals two drives per SCSI channel.
Vista de pagina 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 182 183

Comentarios a estos manuales

Sin comentarios