Hp ProLiant ML350e Gen8 v2-Server Manual de usuario Pagina 61

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 129
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 60
Hardware options installation 61
o
For a redundant power supply
10. Install the PCI air baffle ("PCI air baffle option" on page 38).
11. Install the access panel (on page 26).
12. Return the server to an upright position.
13. Lock the front bezel (on page 24).
14. Connect each power cord to the server.
15. Connect each power cord to the power source.
16. Power up the server (on page 23).
Installing the FBWC module and capacitor pack (B120i)
To install the component:
1. Power down the server (on page 23).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Unlock the front bezel (on page 24).
4. Place the server on its side.
5. Remove the access panel (on page 25).
6. If installed, remove the PCI air baffle (on page 27).
7. Remove any full-length PCI expansion cards installed in PCI slots 3, 4, 5 and 6 ("Remove the full-length
expansion board" on page 29).
Vista de pagina 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 128 129

Comentarios a estos manuales

Sin comentarios