Hp ProLiant ML350p Gen8 Server Manual de usuario Pagina 86

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 145
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 85
Hardware options installation 86
If two fans fail, then the server shuts down.
IMPORTANT: Fan louvers must be present for the redundant configuration. Without the louvers,
all four fans are nonredundant.
NOTE: If your system is already installed with four fans, store the fan that is included in this kit as
a spare.
Installing a hot-plug redundant fan
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 21).
o For rack models, if installed, remove the security bezel (on page 21).
2. Power down the server (on page 20).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
o For tower models, place the server on a flat, level surface with the access panel facing up.
o For rack models, extend the server from the rack (on page 24).
5. Remove the access panel (on page 23).
6. Remove all the fans and fan blanks.
Vista de pagina 85
1 2 ... 81 82 83 84 85 86 87 88 89 90 91 ... 144 145

Comentarios a estos manuales

Sin comentarios