edge switch 2/16 product manager user guide 4–5
Using Logs
Figure 4–3: Event Log
All detected firmware faults and hardware failures are sent to the HAFM server for
recording in the event log. The log provides a maximum of 1000 log entries before it
wraps and overwrites the oldest entries.
For detailed information on event data and problem resolution, refer to the hp
StorageWorks edge switch 2/16 service manual (A7284-96002/AA-RS2JA-TE).
Each log entry includes the following:
•Date/Time
The date and time of the event on the switch.
Event
Events are identified by a unique code.
Event codes include:
Description
A short description of the event.
Severity
There are four classifications of severity that identify the importance of the event.
Informational
Minor
Major
Severe
000 - 199 System events
200 - 299 Power supply events
300 - 399 Fan module events
400 - 499 CTP events
500 - 599 Port events