HP AlphaServer DS25 Instrucciones de operaciones Pagina 218

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 281
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 217
6.6.2 Displaying the System Environment
The RMC env command provides a snapshot of the system environ-
ment.
RMC> env
System Hardware Monitor
System Temperatures (warnings at 50.00C, power-off at 55.00C)
CPU0: 29.00C
CPU1: 33.00C
Zone0: 34.00C
Zone1: 33.00C Zone2: 29.00C
Fan RPMs
Sys Fan0: 2428 Sys Fan1: 2428 PCI Fan: 1695
CPU0 Fan: 3590 CPU1 Fan: 3629
Power Supply(OK, FAIL, OFF, ’----’ means not present)
PS0 : OK PS1 : OK PS2 : OK
CPU0: OK CPU1: OK
CPU CORE voltage
CPU0: +1.650V CPU1: +1.640V
CPU IO voltage
CPU0: +1.650V CPU1: +1.640V
CPU CACHE voltage
CPU0: +2.548V CPU1: +2.522V
Bulk voltage
+3.3V Bulk: +3.326V +5V Bulk: +5.255V +12V Bulk: +12.160V
Vterm: +1.600V Cterm: +1.600V -12V Bulk: -12.537V
+2.5V Bulk: +2.457V
RMC>
6-16 DS25 Owner’s Guide
Vista de pagina 217
1 2 ... 213 214 215 216 217 218 219 220 221 222 223 ... 280 281

Comentarios a estos manuales

Sin comentarios