HP DL120 - ProLiant - G5 Guía para resolver problemas Pagina 162

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 201
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 161
Error messages 162
2.
Be sure the cables to the specified port are connected properly and securely ("Loose connections" on
page 18).
3. Reconfigure the drives to different SCSI ports.
1776-Slot X Drive Array - Shared SAS Port Connection Conflict Detected - Ports 1I,
1E: Storage connections detected on both shared internal and external ports.
...Controller selects internal port until connection is removed from one of the ports.
Audible Beeps: None
Action: For cable configuration information, refer to the controller documentation.
1776-Drive Array Reports Improper SCSI Port 1 Cabling
Audible Beeps: None
Possible Cause:
The integrated array enabler board failed.
The I/O board, drive backplane fan board, or drive backplane failed.
Action:
1. Replace the integrated array enabler board.
2. Update the integrated Smart Array option to the latest firmware version ("Firmware maintenance" on
page 80).
CAUTION: Only authorized technicians trained by HP should attempt to remove the I/O board.
If you believe the I/O board requires replacement, contact HP Technical Support ("Contacting
HP" on page 185, "Contacting HP technical support or an authorized reseller" on page 185)
before proceeding.
3. Reboot the server after replacing each item:
a. Drive backplane fan board
b. Drive backplane
c. I/O board
1777-Slot X Drive Array - Storage Enclosure Problem Detected...
(followed by one or more of the following):
...SCSI Port Y: Cooling Fan Malfunction Detected
SCSI Port Y: Overheated Condition Detected
SCSI Port Y: Side-Panel must be Closed to Prevent Overheating
SCSI Port Y: Redundant Power Supply Malfunction Detected
SCSI Port Y: Wide SCSI Transfer Failed
SCSI Port Y: Interrupt Signal Inoperative
SCSI Port y: Unsupported ProLiant Storage System Detected
Audible Beeps: None
Possible Cause: Environment threshold was violated on the drive enclosure.
Action:
Check the cooling fan operation by placing a hand over the fan.
Vista de pagina 161
1 2 ... 157 158 159 160 161 162 163 164 165 166 167 ... 200 201

Comentarios a estos manuales

Sin comentarios