HP ProCurve 6600-24XG Switch
HP ProCurve 6600-24XG SwitchHP ProCurve 6600-24XG Switch
HP ProCurve 6600-24XG Switch
HP ProCurve 6600-48G Switch
HP ProCurve 6600-48G SwitchHP ProCurve 6600-48G Switch
HP ProCurve 6600-48G Switch
Models
ModelsModels
Models
HP ProCurve 6600-24G Switch
J9263A
HP ProCurve 6600-24G-4XG Switch
J9264A
HP ProCurve 6600-24XG Switch
J9265A
HP ProCurve 6600-48G Switch
J9451A
HP ProCurve 6600-48G-4XG Switch
J9452A
Key features
Key featuresKey features
Key features
Data center server access layer
Front-to-back cooling, redundant power
Layer 2 - Layer 4 and intelligent edge feature set
Enterprise-class performance and security
Scalable 10/100/1000 and 10-GbE connectivity
QuickSpecs
HP ProCurve 6600 Switch Series
HP ProCurve 6600 Switch SeriesHP ProCurve 6600 Switch Series
HP ProCurve 6600 Switch Series
Overview
DA - 13267 Worldwide — Version 3 — June 22, 2009
Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - QuickSpecs

HP ProCurve 6600-24XG SwitchHP ProCurve 6600-24XG SwitchHP ProCurve 6600-24XG SwitchHP ProCurve 6600-24XG Switch HP ProCurve 6600-48G SwitchHP ProCur

Pagina 2

Fan trayFan trayFan trayFan trayincludes: 1 x J9271A1 fan tray slotFan tray supports N+N fans for added redundancy.Physical characteristicsPhysical ch

Pagina 3

NotesNotesNotesNotesIdle power is the actual power consumption of the device with no portsconnected.Maximum power rating is the worst-case theoretical

Pagina 4

RFC 868 Time ProtocolRFC 951 BOOTPRFC 1058 RIPv1RFC 1350 TFTP Protocol (revision 2)RFC 1519 CIDRRFC 1542 BOOTP ExtensionsRFC 2030 Simple Network Time

Pagina 5

RFC 2674 802.1p and IEEE 802.1Q Bridge MIBRFC 2737 Entity MIB (Version 2)RFC 2787 VRRP MIBRFC 2863 The Interfaces Group MIBRFC 2925 Ping MIBNetwork ma

Pagina 6

1000 Mb Latency1000 Mb Latency1000 Mb Latency1000 Mb Latency< 2.1 µs (FIFO 64-byte packets)ThroughputThroughputThroughputThroughputup to 240.2 mill

Pagina 7

FlickerFlickerFlickerFlickerEN 61000-3-3, IEC 61000-3-3ManagementManagementManagementManagementHP ProCurve Manager Plus; HP ProCurve Manager (included

Pagina 8

RFC 2710 Multicast Listener Discovery (MLD) for IPv6RFC 2925 Remote Operations MIB (Ping only)RFC 3019 MLDv1 MIBRFC 3315 DHCPv6 (client only)RFC 3513

Pagina 9

IEEE 802.1X Port Based Network Access ControlRFC 1492 TACACS+RFC 2865 RADIUS (client only)RFC 2866 RADIUS Accounting Secure Sockets Layer (SSL)SSHv2 S

Pagina 10

AcousticAcousticAcousticAcousticISO 7779, ISO 9296Electrical characteristicsElectrical characteristicsElectrical characteristicsElectrical characteris

Pagina 11

UDLD (Uni-directional Link Detection)RFC 826 ARPRFC 854 TELNETRFC 868 Time ProtocolRFC 951 BOOTPRFC 1058 RIPv1RFC 1350 TFTP Protocol (revision 2)RFC 1

Pagina 12

IntroductionIntroductionIntroductionIntroductionThe HP ProCurve 6600 Switch Series consists of the most advanced data center server edge switches in t

Pagina 13

RFC 2620 RADIUS Accounting MIBRFC 2665 Ethernet-Like-MIBRFC 2668 802.3 MAU MIBRFC 2674 802.1p and IEEE 802.1Q Bridge MIBRFC 2737 Entity MIB (Version 2

Pagina 14

Memory and processorMemory and processorMemory and processorMemory and processorProcessor type and speedProcessor type and speedProcessor type and spe

Pagina 15

FlickerFlickerFlickerFlickerEN 61000-3-3, IEC 61000-3-3ManagementManagementManagementManagementHP ProCurve Manager Plus; HP ProCurve Manager (included

Pagina 16

RFC 2710 Multicast Listener Discovery (MLD) for IPv6RFC 2925 Remote Operations MIB (Ping only)RFC 3019 MLDv1 MIBRFC 3315 DHCPv6 (client only)RFC 3513

Pagina 17

IEEE 802.1X Port Based Network Access ControlRFC 1492 TACACS+RFC 2865 RADIUS (client only)RFC 2866 RADIUS Accounting Secure Sockets Layer (SSL)SSHv2 S

Pagina 18

serviceabilityPower down idle portsPower down idle portsPower down idle portsPower down idle ports: power down blocks of idle Gigabit and 10GbE ports

Pagina 19

physical connections; enables load-balancing and increases resiliencySparing simplicitySparing simplicitySparing simplicitySparing simplicity: common

Pagina 20

Access control listsAccess control listsAccess control listsAccess control lists (ACLs): provide filtering based on the IP field, source/destination I

Pagina 21

HP ProCurve 6600-24GHP ProCurve 6600-24GHP ProCurve 6600-24GHP ProCurve 6600-24GSwitchSwitchSwitchSwitch(J9263A)PortsPortsPortsPorts20 auto-sensing 10

Pagina 22

between 100-120 and 200-240 volts and either50 or 60 HzMaximum heat dissipationMaximum heat dissipationMaximum heat dissipationMaximum heat dissipatio

Pagina 23

IEEE 802.3x Flow ControlRFC 768 UDPRFC 783 TFTP Protocol (revision 2)RFC 792 ICMPRFC 793 TCPUDLD (Uni-directional Link Detection)RFC 826 ARPRFC 854 TE

Pagina 24

RFC 1850 OSPFv2 MIBRFC 2021 RMONv2 MIBRFC 2096 IP Forwarding Table MIBRFC 2613 SMON MIBRFC 2618 RADIUS Client MIBRFC 2620 RADIUS Accounting MIBRFC 266