4. Pull the fan straight up and out of the chassis.
CAUTION: To prevent server components from overheating, replace the fan within 20
seconds. Failure to observe this caution results in the server automatically shutting down
to prevent an overtemperature condition.
Figure 6-5 Removing and Replacing a Hot-Swappable Chassis Fan Unit
Fan Unit 1
Fan Unit 2
Fan Unit 3
Replacing a Hot-Swappable Chassis Fan Unit
CAUTION: To prevent server components from overheating, replace the fan within 20 seconds.
Failure to observe this caution results in the server automatically shutting down to prevent an
overtemperature condition.
NOTE: The fan unit is keyed to fit into the fan housing in the correct orientation only.
To replace a hot-swappable chassis fan unit, follow these steps:
1. Push the fan unit firmly into the fan housing until it is flush with the top of the chassis.
NOTE: It can take up to ten seconds after installation for the new fan LED to turn off.
2. Check the diagnostic LED that corresponds to the replaced fan unit.
Removing and Replacing a Hot-Swappable Chassis Fan Unit 185