Pagina 1 - Troubleshooting Guide

HP ProLiant Servers Troubleshooting Guide June 2006 (Fifth Edition) Part Number 375445-005

Pagina 2 - Audience assumptions

Introduction 10 Introduction In this section What's new...

Pagina 3 - Contents

Error messages 100 1. Enable OBDR 2. Exit Audible Beeps: None Possible Cause: A USB tape device that supports One Button Disaster Recovery (OBDR) is

Pagina 4 - Contents 4

Error messages 101 100 Series 101-I/O ROM Error Audible Beeps: None Possible Cause: Options ROM on a PCI, PCI-X, or PCI Express device is corrupt. A

Pagina 5 - Contents 5

Error messages 102 102-System Board Failure, DMA Test Failed Audible Beeps: None Possible Cause: 8237 DMA controllers, 8254 timers, and similar devi

Pagina 6 - Contents 6

Error messages 103 180-Log Reinitialized Audible Beeps: None Possible Cause: The IML has been reinitialized due to corruption of the log. Action: Ev

Pagina 7 - Contents 7

Error messages 104 207-Invalid Memory Configuration - Incomplete Bank Detected in Bank X Audible Beeps: 1 long, 1 short Possible Cause: Bank is miss

Pagina 8 - Contents 8

Error messages 105 207-Invalid Memory Configuration - Unsupported DIMM in Socket X Audible Beeps: 1 long, 1 short Possible Cause: Unregistered DIMMs

Pagina 9 - Contents 9

Error messages 106 210-Memory Board Power Fault on board X Audible Beeps: 1 long, 1 short Possible Cause: A problem exists with a memory board power

Pagina 10 - Introduction

Error messages 107 303-Keyboard Controller Error Audible Beeps: None Possible Cause: System board, keyboard, or mouse controller failure occurred. A

Pagina 11 - Getting started

Error messages 108 600 Series 601-Diskette Controller Error Audible Beeps: None Possible Cause: Diskette controller circuitry failure occurred. Acti

Pagina 12 - Pre-diagnostic steps

Error messages 109 2. Run Insight Diagnostics ("HP Insight Diagnostics" on page 61) and replace failed components as indicated. 1100 Seri

Pagina 13 - Warnings and cautions

Getting started 11 • Updated contacting HP: • Contacting HP technical support or an authorized reseller • Server information you need Getting st

Pagina 14 - Symptom information

Error messages 110 1611-CPU Zone Fan Assembly Failure Detected. Single fan... ...failure. Assembly will provide adequate cooling. Audible Beeps: Non

Pagina 15 - Common problem resolution

Error messages 111 1611-Fan x Not Present (Fan Zone I/O) Audible Beeps: 2 short Possible Cause: Required fan is not installed or spinning. Action: 1

Pagina 16 - Hard drive guidelines

Error messages 112 1615-Power Supply Configuration Error Audible Beeps: None Possible Cause: The server configuration requires an additional power s

Pagina 17

Error messages 113 Audible Beeps: None Possible Cause: Upgrade the Array Accelerator module to a larger size. Action: Migrate logical drives to RAID

Pagina 18

Error messages 114 1720-S.M.A.R.T. Hard Drive Detects Imminent Failure Audible Beeps: None Possible Cause: A hard drive SMART predictive failure con

Pagina 19 - Diagnostic flowcharts

Error messages 115 1727-Slot X Drive Array - New Logical Drive(s) Attachment Detected... ...If more than 32 logical drives, this message will be fol

Pagina 20 - General diagnosis flowchart

Error messages 116 Expansion will resume when automatic data recovery has been completed. Audible Beeps: None Possible Cause: The capacity expansion

Pagina 21 - Diagnostic flowcharts 21

Error messages 117 1774-Slot X Drive Array - Obsolete Data Found in Array Accelerator Audible Beeps: None Possible Cause: Drives were used on anothe

Pagina 22 - Power-on problems flowchart

Error messages 118 1776-Drive Array Reports Improper SCSI Port 1 Cabling Audible Beeps: None Possible Cause: • The integrated array enabler board f

Pagina 23

Error messages 119 1779-Slot X Drive Array - Replacement drive(s) detected OR previously failed drive(s) now operational:... ...Port Y: SCSI ID Z: R

Pagina 24

Getting started 12 Pre-diagnostic steps WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server d

Pagina 25

Error messages 120 2. Be sure all drives are fully seated. 3. Replace defective cables, drive X, or both. 1785-Slot X Drive Array Not Configured..

Pagina 26 - POST problems flowchart

Error messages 121 1786-Slot 1 Drive Array Recovery Needed. Automatic Data Recovery Previously Aborted!... ...The following SCSI drive(s) need Autom

Pagina 27 - Diagnostic flowcharts 27

Error messages 122 a. Repair the connection and press the F2 key. b. If the problem persists, run ADU ("Array Diagnostic Utility" on page

Pagina 28

Error messages 123 1794-Drive Array - Array Accelerator Battery Charge Low... ...Array Accelerator is temporarily disabled. Array Accelerator will b

Pagina 29

Error messages 124 Audible Beeps: None Possible Cause: One or more logical drives failed due to loss of data in posted-writes memory. Action: • Pr

Pagina 30

Error messages 125 Automatic operating system shutdown initiated due to fan failure Event Type: Fan failure Action: Replace the fan. Automatic Oper

Pagina 31 - Diagnostic flowcharts 31

Error messages 126 Real-Time Clock Battery Failing Event Type: System configuration battery low Action: Replace the system configuration battery. S

Pagina 32 - Hardware problems

Error messages 127 Event Type: Host bus error CAUTION: Only authorized technicians trained by HP should attempt to remove the system board. If yo

Pagina 33 - General hardware problems

Error messages 128 1. Press the server blade management module reset button. 2. Replace the server blade management module. Server blade managemen

Pagina 34 - Unknown problem

Error messages 129 Interconnect B Error Code LED code: 14-1, 14-2, 14-3, or 14-4 Location: Interconnect device - side B Action: Perform the followin

Pagina 35 - Internal system problems

Getting started 13 weight in kg weight in lb This symbol indicates that the component exceeds the recommended weight for one individual to handle

Pagina 36 - Diskette drive problems

Error messages 130 For more information, refer to the HP BladeSystem Maintenance and Service Guide on the HP website (http://www.hp.com/products/ser

Pagina 37 - Tape drive problems

Error messages 131 Power management module board error codes LED code: 7-1, 7-2, 7-3, 7-4, 7-5, 7-6, 7-7, 7-8, 7-9, 7-10, 7-11, 7-12, or 7-13 Locati

Pagina 38 - Media issue

Error messages 132 IMPORTANT: Reboot the server after completing each numbered step. If the error condition continues, proceed with the next step

Pagina 39 - Hard drive problems

Error messages 133 3. Reseat the remaining memory boards, rebooting after each installation to isolate any failed memory boards, if applicable. 4.

Pagina 40 - Fan problems

Error messages 134 IMPORTANT: Processor socket 1 and PPM slot 1 must be populated at all times or the server does not function properly. • PPMs,

Pagina 41 - Memory problems

Error messages 135 Description: The system encountered an NMI prior to this boot. The NMI source was: Uncorrectable cache memory error. Action: Repl

Pagina 42 - Processor problems

Error messages 136 MSG_CPU_RR_7 Event type: CPU speed is out of range. Action: Replace the processor. MSG_CPU_RR_8 Event type: Unable to update the

Pagina 43 - External device problems

Error messages 137 Action: Replace the processor. MSG_CPU_RR_17 Event type: Stress integer math test has failed. Action: • Ensure proper ventilati

Pagina 44 - Mouse and keyboard problems

Contacting HP 138 Contacting HP In this section Contacting HP technical support or an authorized reseller...

Pagina 45 - Modem problems

Contacting HP 139 Server information you need Before contacting HP technical support, collect the following information: • Explanation of the issue

Pagina 46

Getting started 14 CAUTION: The server is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord int

Pagina 47 - Network controller problems

Contacting HP 140 • An updated Emergency Repair Diskette • If HP drivers are installed: • Version of the PSP used • List of drivers from the PSP

Pagina 48

Contacting HP 141 Novell NetWare operating systems Collect the following information: • Whether the operating system was factory installed • Opera

Pagina 49 - Software problems

Contacting HP 142 • If management agents are installed, version number of the agents • System dumps, if they can be obtained (in case of panics) •

Pagina 50 - Operating system updates

Contacting HP 143 • DU number • List of drivers in the DU diskette • The drive subsystem and file system information: • Number and size of partit

Pagina 51

Acronyms and abbreviations 144 Acronyms and abbreviations ACPI Advanced Configuration and Power Interface ACU Array Configuration Utility ADG Adva

Pagina 52 - Remote ROM flash problems

Acronyms and abbreviations 145 IDE integrated device electronics iLO Integrated Lights-Out IMD Integrated Management Display IML Integrated Manag

Pagina 53

Acronyms and abbreviations 146 ORCA Option ROM Configuration for Arrays OS operating system POST Power-On Self Test PPM processor power module P

Pagina 54 - Software tools and solutions

Acronyms and abbreviations 147 SMART self-monitoring analysis and reporting technology SNMP Simple Network Management Protocol SSD support softwar

Pagina 55 - HP ROM-Based Setup Utility

Index 148 1 120PCI.HAM 50 A accelerator error log 73 accelerator status 74, 75, 76 ACPI support 50 ACU (Array Configuration Utility) 54 ada

Pagina 56 - BIOS Serial Console

Index 149 diskette image creation 57 DMA error 94 documentation 69, 70 drive errors 36, 37, 78, 79, 80, 90, 97, 108 drive failure, detecting

Pagina 57

Common problem resolution 15 Common problem resolution In this section Loose connections ...

Pagina 58 - Management tools

Index 150 Management Agents 59 Management CD 58, 70, 71 management tools 58 media issue, tape drive 38 MEGA4 XX.HAM 50 memory 41, 56, 71,

Pagina 59 - Management Agents

Index 151 read/write errors 36, 37 read/write issue, tape drive 38 redundant ROM 65, 98, 113 registering the server 71 Remote Insight Lights-

Pagina 60 - HP Control Tower

Index 152 W warnings 13, 72 Web-Based Enterprise Service 63 website, HP 69, 70 white papers 70, 72 Windows Event Log processor error codes

Pagina 61 - Diagnostic tools

Common problem resolution 16 Components for option firmware updates are also available from the HP Storage Products Software and Drivers website (ht

Pagina 62 - Integrated Management Log

Common problem resolution 17 Activity LED (1) Online LED (2) Fault LED (3) Interpretation On Off Off Do not remove the drive. The drive is being ac

Pagina 63 - Keeping the system current

Common problem resolution 18 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Flashing irregularly Amber, flashing regularly (1

Pagina 64

Diagnostic flowcharts 19 Diagnostic flowcharts In this section Troubleshooting flowcharts ...

Pagina 65 - Firmware maintenance

© Copyright 2004-2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warra

Pagina 66 - Offline ROM flash technology

Diagnostic flowcharts 20 Start diagnosis flowchart Use the following flowchart to start the diagnostic process. General diagnosis flowchart

Pagina 67 - Updating firmware

Diagnostic flowcharts 21 The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of the problem, or if the

Pagina 68

Diagnostic flowcharts 22 Power-on problems flowchart Server power-on problems flowchart Symptoms: • The server does not power on. • The system pow

Pagina 69 - Online resources

Diagnostic flowcharts 23 p-Class server blade power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is o

Pagina 70 - General server resources

Diagnostic flowcharts 24 • Loose or faulty power cord • Power source problem • Power-on circuit problem • Improperly seated component or interloc

Pagina 71

Diagnostic flowcharts 25 c-Class server blade power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off

Pagina 72 - Technical topics

Diagnostic flowcharts 26 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system a

Pagina 73 - Error messages

Diagnostic flowcharts 27 Server and p-Class server blade POST problems flowchart

Pagina 74 - Error messages 74

Diagnostic flowcharts 28 c-Class server blade POST problems flowchart Operating system boot problems flowchart Symptoms: • Server does not boot a

Pagina 75 - Error messages 75

Diagnostic flowcharts 29 • Use iLO to remotely attach virtual devices to mount the SmartStart CD onto the server blade. • Use a local I/O cable and

Pagina 76 - Error messages 76

Contents 3 Contents Introduction...

Pagina 77 - Error messages 77

Diagnostic flowcharts 30 NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation. Possible cau

Pagina 78 - 3. Power up the system

Diagnostic flowcharts 31 c-Class server blade fault indications flowchart

Pagina 79

Hardware problems 32 Hardware problems In this section Procedures for all ProLiant servers ...

Pagina 80

Hardware problems 33 UPS problems UPS is not working properly Action: 1. Be sure the UPS batteries are charged to the proper level for operation. S

Pagina 81

Hardware problems 34 2. Refer to the release notes included with the hardware to be sure the problem is not caused by a change to the hardware relea

Pagina 82

Hardware problems 35 • If the system boots and video is working, add each component back to the server one at a time, restarting the server after ea

Pagina 83

Hardware problems 36 3. Be sure no loose connections (on page 15) exist. 4. Be sure the media from which you are attempting to boot is not damaged

Pagina 84

Hardware problems 37 Drive is not found Action: Be sure no loose connections (on page 15) exist with the drive. Non-system disk message is displaye

Pagina 85

Hardware problems 38 Read/write issue Action: 1. Run the Acceptance Test in HP StorageWorks Library and Tape Tools. CAUTION: Running the Accepta

Pagina 86 - Error messages 86

Hardware problems 39 Hard drive problems System completes POST but hard drive fails Action: 1. Be sure no loose connections (on page 15) exist. 2.

Pagina 87

Contents 4 Video problems...

Pagina 88

Hardware problems 40 1. Be sure the files are not corrupt. Run the repair utility for the operating system. 2. Be sure no viruses exist on the serv

Pagina 89

Hardware problems 41 Memory problems General memory problems are occurring Action: • Isolate and minimize the memory configuration. • Be sure th

Pagina 90

Hardware problems 42 Server fails to recognize new memory Action: 1. Be sure the memory is the correct type for the server and is installed accordi

Pagina 91 - Error messages 91

Hardware problems 43 c. Replace the remaining processor with a known functional processor. If the problem is resolved after you restart the server,

Pagina 92 - Wrong Accelerator

Hardware problems 44 7. Be sure a video expansion board, such as a RILOE board, has not been added to replace onboard video, making it seem like the

Pagina 93 - Error messages 93

Hardware problems 45 Audio problems Action: Be sure the server speaker is connected. Refer to the server documentation. Printer problems Printer d

Pagina 94 - Error messages 94

Hardware problems 46 Data is displayed as garbled characters after the connection is established Action: 1. Be sure both modems have the same setti

Pagina 95 - Error messages 95

Hardware problems 47 3. Be sure no line interference exists. Retry the connection by dialing the number several times. If conditions remain poor, co

Pagina 96 - Error messages 96

Hardware problems 48 2. Be sure the correct network driver is installed for the controller and that the driver file is not corrupted. Reinstall the

Pagina 97

Software problems 49 Software problems In this section Operating system problems and resolutions...

Pagina 98 - • Install a power supply

Contents 5 Clustering software...

Pagina 99 - 1. Power down the server

Software problems 50 If neither of these actions resolve the problem, contact an authorized service provider. For more information about debugging t

Pagina 100

Software problems 51 3. Install the current drivers. If you apply the update and have problems, refer to the Software and Drivers Download website (

Pagina 101 - 100 Series

Software problems 52 • Linux—Refer to the operating system documentation for information. Linux operating systems For troubleshooting information s

Pagina 102 - Error messages 102

Software problems 53 • One or more remote servers with system ROMs requiring upgrade • An administrative user account on each target system. The ad

Pagina 103 - 200 Series

Software tools and solutions 54 Software tools and solutions In this section Configuration tools...

Pagina 104 - Error messages 104

Software tools and solutions 55 • Installing software drivers directly from the CD. With systems that have internet connection, the SmartStart Autor

Pagina 105 - Error messages 105

Software tools and solutions 56 Auto-configuration process The auto-configuration process automatically runs when you boot the server for the first

Pagina 106 - 300 Series

Software tools and solutions 57 7. Press the Esc key to exit the current menu, or press the F10 key to exit RBSU. For more information on online spa

Pagina 107 - 400 Series

Software tools and solutions 58 Management CD The Management CD contains the latest tools available for easily managing the server, such as HP SIM (

Pagina 108 - 600 Series

Software tools and solutions 59 • Access advanced troubleshooting features through the iLO and iLO 2 interface. • Diagnose iLO and iLO 2 using HP S

Pagina 109 - 1600 Series

Contents 6 Teardown procedures, part numbers, specifications ... 72 Technical

Pagina 110 - 1611-Fan Failure Detected

Software tools and solutions 60 The Virtual Machine Management Pack provides the following functionality: • Central management and control of VMwar

Pagina 111

Software tools and solutions 61 System Management homepage To access the System Management homepage of a server, go to https://localhost:2381 (htt

Pagina 112 - 1700 Series

Software tools and solutions 62 Smart Array SCSI Diagnosis feature NOTE: This feature is only available in HP Insight Diagnostics Online Edition.

Pagina 113

Software tools and solutions 63 Array Diagnostic Utility ADU is a tool that collects information about array controllers and generates a list of det

Pagina 114

Software tools and solutions 64 If you do not use the SmartStart CD to install an operating system, drivers for some of the new hardware are require

Pagina 115 - Error messages 115

Software tools and solutions 65 Care Pack HP Care Pack Services offer upgraded service levels to extend and expand standard product warranty with ea

Pagina 116 - Previous Power Up

Software tools and solutions 66 For additional information, refer to the HP Online ROM Flash User Guide on the HP website (http://h18023.www1.hp.com

Pagina 117

Software tools and solutions 67 2. Shut down each server where the system or option ROM images are to be upgraded and reboot using the correct ROMPa

Pagina 118

Software tools and solutions 68 4. Verify the firmware update by checking the version of the current firmware.

Pagina 119

HP resources for troubleshooting 69 HP resources for troubleshooting In this section Online resources ...

Pagina 120

Contents 7 Drive Time-Out Occurred on Physical Drive Bay X... 80 Drive X I

Pagina 121

HP resources for troubleshooting 70 White papers White papers are electronic documentation on complex technical topics. Some white papers contain in

Pagina 122

HP resources for troubleshooting 71 Management of the server Refer to the HP Systems Insight Manager Help Guide on the Management CD or the HP websi

Pagina 123 - Error messages 123

HP resources for troubleshooting 72 Server and option specifications, symbols, installation warnings, and notices Refer to the server documentation

Pagina 124 - Event list error messages

Error messages 73 Error messages In this section ADU error messages...

Pagina 125 - Error messages 125

Error messages 74 Accelerator Parity Write Errors: X Description: Number of times that write memory parity errors were detected during transfers to

Pagina 126 - Error messages 126

Error messages 75 Description: The number of cache lines experiencing excessive ECC errors has reached a preset limit. Therefore, the cache has been

Pagina 127 - Server blade error codes

Error messages 76 Accelerator Status: Valid Data Found at Reset Description: Valid data was found in posted-write memory at reinitialization. Data w

Pagina 128 - Interconnect A Error Code

Error messages 77 Cache Has Been Disabled; Likely Caused By a Loose Pin on One of the RAM Chips Description: Cache has been disabled due to a large

Pagina 129 - Interconnect B Error Code

Error messages 78 page 63) examines each physical drive and looks for drives that have been moved to a different drive bay. Action: Look for message

Pagina 130 - Power supply error codes

Error messages 79 4. If the problem persists, power down the system and replace the cable. 5. If the problem persists, power down the system and re

Pagina 131

Contents 8 Swapped Cables or Configuration Error Detected. A Drive Rearrangement... 88 Swapped Cables or Conf

Pagina 132 - Memory-related port 85 codes

Error messages 80 Drive Monitoring Features Are Unobtainable Description: ADU ("Array Diagnostic Utility" on page 63) is unable to get mon

Pagina 133 - Miscellaneous port 85 codes

Error messages 81 Identify Logical Drive Data did not Match with NVRAM Description: The identify unit data from the array controller does not match

Pagina 134 - Message ID: 4190

Error messages 82 Action: Check for drive failures, wrong drive replaced, or loose cable messages. If a drive failure occurred, replace the failed d

Pagina 135 - MSG_CPU_RR_6

Error messages 83 Logical Drive X Status = Wrong Drive Replaced Description: A physical drive in this logical drive has failed. The incorrect drive

Pagina 136 - Error messages 136

Error messages 84 Other Controller Indicates Different Firmware Version Description: The other controller in the redundant controller configuration

Pagina 137 - MSG_CPU_RR_17

Error messages 85 5. If the error persists after completing steps 1 through 4, contact an HP authorized service provider. SCSI Port X Drive ID Y Fa

Pagina 138 - Contacting HP

Error messages 86 Description: A predictive failure warning for this hard drive has been generated, indicating that a drive failure is imminent. Act

Pagina 139 - Server information you need

Error messages 87 Description: A power supply in the external storage unit has failed. Action: Replace the power supply. Storage Enclosure on SCSI

Pagina 140 - Linux operating systems

Error messages 88 Swapped cables or configuration error detected. A configured array of drives... ...was moved from another controller that supporte

Pagina 141 - SCO operating systems

Error messages 89 Swapped cables or configuration error detected. The configuration information on the attached drives... ...is not backward compati

Pagina 142 - IBM OS/2 operating systems

Contents 9 System Power Supply Failure (Power Supply X)... 126 Unrecover

Pagina 143

Error messages 90 Description: ADU detected two different controller models installed in a redundant controller configuration. This is not supported

Pagina 144 - Acronyms and abbreviations

Error messages 91 Unsupported Processor Configuration (Processor Required in Slot #1) Description: Processor required in slot 1. Action: If you do n

Pagina 145

Error messages 92 WARNING: Storage Enclosure on SCSI Bus X Indicated it is Operating in Single Ended Mode... ...SOLUTION: This usually occurs when a

Pagina 146

Error messages 93 Non-numeric messages or beeps only Advanced Memory Protection mode: Advanced ECC Audible Beeps: None Possible Cause: Advanced ECC

Pagina 147

Error messages 94 Critical Error Occurred Prior to this Power-Up Audible Beeps: None Possible Cause: A catastrophic system error, which caused the s

Pagina 148 - Index 148

Error messages 95 Fatal Hub Link Error Audible Beeps: None Possible Cause: The hub link interface has experienced a critical failure that caused an

Pagina 149 - Index 149

Error messages 96 Invalid memory types were found on the same node. Please check DIMM compatibility. - Some DIMMs may not be used Description: Inval

Pagina 150 - Index 150

Error messages 97 NMI - Undetermined Source Audible Beeps: None Possible Cause: An NMI event has occurred. Action: Reboot the server. Node Interlea

Pagina 151 - Index 151

Error messages 98 Power Fault Detected in Hot-Plug PCI Slot x Audible Beeps: 2 short Possible Cause: PCI-X Hot Plug expansion slot was not powered u

Pagina 152 - Index 152

Error messages 99 Temperature violation detected - system Shutting Down in x seconds Audible Beeps: 1 long, 1 short Possible Cause: The system has r