HP ProLight Server Manual de usuario Pagina 135

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 152
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 134
Error messages 135
Description: The system encountered an NMI prior to this boot. The NMI source was: Uncorrectable
cache memory error.
Action: Replace the processor.
Insight Diagnostics processor error codes
MSG_CPU_RR_1
Event type: Unable to divide and multiply with zero and infinity.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.
MSG_CPU_RR_2
Event type: A Pentium floating point bug exists.
Action: Replace the processor.
MSG_CPU_RR_3
Event type: Coprocessor geometric series is out of range.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.
MSG_CPU_RR_5
Event type: Refresh count is out of range.
Action: Replace the board that contains the memory controller.
MSG_CPU_RR_6
Event type: Unable to perform arithmetic operations on registers.
Action:
Ensure proper ventilation and cooling for the server.
Ensure the processor heatsinks are attached correctly (do not remove them).
Check diagnostics and the Integrated Management Log for heat-related events.
Upgrade to the latest versions of system BIOS and Insight Diagnostics.
Replace the processor.
Vista de pagina 134
1 2 ... 130 131 132 133 134 135 136 137 138 139 140 ... 151 152

Comentarios a estos manuales

Sin comentarios