#1
The path information is displayed only when a value is specified for the -
path -item parameter.
#2
This storage system applies when the dynamic I/O path control function is
disabled.
Table 6-13 Elements of a Path Name
Element AIX representation
Corresponding
information
HBA adapter number
(example: 08)
#1
HBA adapter number The HBA adapter number,
which is displayed by
executing the lsdev -Cc
disk command
Bus number (example:
14)
#1
PCI bus number The parent bus number,
which is displayed by
executing the lsdev -Cc
disk command
Adapter type (example:
00)
#2
None Always 00
Adapter number (example:
01)
#2
fscsi number (the xx part
of fscsixx)
The fscsi number, which is
displayed by executing the
lsdev -C command
Target ID (example:
00000000000000E2)
Target ID The value of scsi_id, which
is displayed by executing
the lsattr -El hdisk-name
command
Host LU number(example:
0001)
Logical unit ID or LUN The value of lun_id, which
is displayed by executing
the lsattr -El hdisk-name
command
#1
This element is applied when the NPIV option is set to off for the
dlmodmset utility for setting the HDLM execution environment ODM.
#2
This element is applied when the NPIV option is set to on for the
dlmodmset utility for setting the HDLM execution environment ODM.
6-52