HP P9500 Manual de usuario Pagina 306

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 494
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 305
| -v {on | off}
| -j {on | off}} [-s]
| -o
| -h }
Parameters
-r { on | off }
Enables or disables the LUN RESET option.
on: Enable
off: Disable
The default is off.
To use GPFS, specify on.
You do not need to reconfigure the hdisk or restart the host when you
change this parameter.
-i { on | off }
Prevents I/O on the Online(E) path.
on: Prevents I/O on the Online(E) path.
off: Allows I/O on the Online(E) path.
The default is off.
When an error (such as one that might occur in a LVM mirror
configuration) is detected and I/O access for a path in the Online(E)
status continues, detection of errors will continue. When this parameter is
set to on, I/O access is suppressed until troubleshooting measures are
taken. This can shorten the time needed to deal with the problem.
You do not need to reconfigure the hdisk or restart the host when you
change this parameter.
Note
When this parameter is set to on, I/O access to the Online(E) path will
be suppressed, so I/O success will automatically change the path to
the Online status. To recover the path, use an online command or
the auto failback function.
-v { on | off }
Enables or disables the NPIV option.
on: Enable
off: Disable
The default is off.
To use HDLM in a client partition to which a virtual HBA is applied by
using the NPIV functionality of the virtual I/O server, specify on. For
details, see
Notes on the Virtual I/O Server on page 3-14.
-j {on | off}
Sets whether to output HDLM messages to the OS error log.
on: Output messages.
7-22
Utility Reference
Hitachi Dynamic Link Manager User Guide for AIX
®
Vista de pagina 305
1 2 ... 301 302 303 304 305 306 307 308 309 310 311 ... 493 494