Hp Insight Cluster Management Utility Manual de usuario Pagina 82

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 191
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 81
#- Native
#cpuload "% cpu load (raw)"1 numerical MeanOverTime 100 % awk '/cpu / {printf"%d\n",$2+$3+$4}' /proc/stat
#- Collectl
cpuload "% cpu load (normalized)" 1 numerical Instantaneous 100 % COLLECTL (cputotals.user) + (cputotals.nice)
+ (cputotals.sys)
The command field must start with the string “COLLECTL” in capital letters. The line continues with
a series of collectl variables included in parenthesis and connected with arithmetical operators.
For this example, the cpuload metric reports the sum of cputotals.user, cputotals.nice, and
cputotals.sys.
For a full list of available collectl variables, run the collectl command interactively, as
follows:
# collectl c 1 -s+C --export lexpr
The -c 1 option runs one shot only. The command output is the list of collectl variables and
the current value:
waiting for 1 second sample...
sample.time 1217858718.002
cputotals.user 1
cputotals.nice 0
cputotals.sys 0
cputotals.wait 7
cputotals.irq 0
cputotals.soft 0
cputotals.steal 0
cputotals.idle 90
ctxint.ctx 239
ctxint.int 1073
ctxint.proc 4
ctxint.runq 152
disktotals.reads 0
disktotals.readkbs 0
disktotals.writes 11
disktotals.writekbs 80
nettotals.kbin 4
nettotals.pktin 49
nettotals.kbout 6
nettotals.pktout 17
cpuinfo.user.cpu0 0
cpuinfo.nice.cpu0 0
cpuinfo.sys.cpu0 0
cpuinfo.wait.cpu0 0
cpuinfo.irq.cpu0 0
cpuinfo.soft.cpu0 0
cpuinfo.steal.cpu0 0
cpuinfo.idle.cpu0 100
cpuinfo.intrpt.cpu0 0
cpuinfo.user.cpu1 0
cpuinfo.nice.cpu1 0
cpuinfo.sys.cpu1 0
cpuinfo.wait.cpu1 11
cpuinfo.irq.cpu1 0
cpuinfo.soft.cpu1 0
cpuinfo.steal.cpu1 0
cpuinfo.idle.cpu1 89
cpuinfo.intrpt.cpu1 0
cpuinfo.user.cpu2 4
cpuinfo.nice.cpu2 0
cpuinfo.sys.cpu2 2
cpuinfo.wait.cpu2 0
Create the monitoring lines by using these variables.
Native HP Insight CMU lines and collectl lines can be mixed in the
ActionAndAlertFile.txt file.
82 Monitoring a cluster with HP Insight CMU
Vista de pagina 81