Hp Unified Extensible Firmware Interface Manual de usuario Pagina 59

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 158
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 58
Figure 49 Server Availability ASR Timeout screen
Setting Thermal Shutdown
Initiate a shutdown due to non-redundant fan failures or temperature increases beyond the pre-set
threshold. If disabled, the System Management Driver ignores thermal events and the system
immediately powers off in data-destructive situations.
To set thermal shutdown:
1. From the System Utilities screen, select System ConfigurationBIOS/Platform Configuration
(RBSU)Server Availability and select Thermal Shutdown and press Enter.
2. Select one of the following options:
Enabled—Allows the Advanced System Management Driver to initiate a system shutdown
when the temperature reaches within 5 degrees of critical level.
Disabled (default)—Allows the Advanced System Management Driver to shut down the
system at critical level.
3. Press F10 to save your selection.
Accessing the BIOS/Platform Configuration (RBSU) menu 59
Vista de pagina 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 157 158

Comentarios a estos manuales

Sin comentarios