Workload protection Page 351 of 677
11. Add the following line to the failback script file, substituting your Storage Mirroring
Recover directory for install_location.
nsupdate.exe "c:\install_location\dnsback.txt"
12. Save the failback script file.
13. Create a text file, called dnsback.txt in the Storage Mirroring Recover directory.
14. Add the following lines to the dnsback.txt file, substituting your target name, fully-
qualified domain name, source name, and source IPaddress as appropriate.
update delete target_server_name.fully_qualified_domain_name.com A
update add source_server_name.fully_qualified_domain_name.com 86400 A
source_server_IP_address
send
15. Save the dnsback.txt file.
16. Change the Storage Mirroring service on the target server to a domain account that
has rights to modify BIND DNS. Stop and start the service to have it take effect.