A - 6
Failover
Get
Get Local
Command FAILOVER
Description Manually initiates the failover process for the specified monitor machine
Syntax
FAILOVER <monitor> [ON <target_machine>]
Options monitor—Name of the source machine designated as the monitor
target_machine—Name of the target machine
Examples
failover indy on jersey
Notes Machine names that contain non-alphanumeric characters must be enclosed in quotation marks.
Command GET
Description The Text Client/DTCL sends a request to Storage Mirroring to return the value of a Storage
Mirroring program setting. The setting is retrieved by Storage Mirroring from the registry.
Syntax
GET <option> [machine]
Options option—See Storage Mirroring Text Client program settings on page 14-11.
machine—Name of the machine
Examples
get netport
get VerifyLogName
get DefaultAddress
Notes If you do not specify a machine name, the value from the current source will be returned. If you
have not identified an active source, no data will be returned.
Machine names that contain non-alphanumeric characters must be enclosed in quotation marks.
Command GETLOCAL
Description The Text Client/DTCL sends a request directly to the registry, bypassing Storage Mirroring, to
return the value of a Storage Mirroring program setting.
Syntax
GETLOCAL <option>
Options option
Examples
getlocal netport
getlocal VerifyLogName
getlocal DefaultAddress