11 . View the messages displayed on the array controller LCD panel during startup to conrm that the
rmware was installed successfully and that the array controller restarts successfully.
NOTE:
In dual-controller congurations, rmware on the two controllers is compared each time
the MSA chassis is restarted. If the versions are mismatched, the system prompts to clone
the rmware on the controller with the latest version over to the controller with the earlier
version rmware. (For the system to operate in a dual-controller mode, rmware on the
controllers must match.)
The following message is displayed on the LCD panel of the controller with the earlier
rmware:
07 CLONE FIRMWARE ? ‘<‘ = NO, ‘>’ = YES
Press the > button on the LCD panel to clone the rmware. During the cloning process,
informational messages are displayed on the controller LCD panels. When the cloning
process is complete, the just-updated controller automatically restarts.
Updating hard drive rmware
SCSI hard drive rmware updates are performed using les on the ProLiant Firmware Maintenance CD
and are required only when the following message is displayed on the MSA controller LCD panel:
85 BAD DRIVE FRMWARE BOX <n> BAY <n>
CAUTION:
Before downloading new rmware,makenoteofthefollowing:
Update system rmware during a scheduled maintenance window.
Stop all host trafc to the array controller during the updating process.
Make sure that a recent, known good back up of all data on the MSA array is available before
updating system rmware.
Make sure that a copy of the conguration, including the iSCSI IP addressing and portal information,
along with the hard drive, LUN, and target information is available before updating system rmware.
If it has been more than six months since you restarted your MSA storage system, HP recommends
that you power-cycle the MSA (power off, and then power on) before updating the rmware to
ensure that you are working with a fresh system.
After the update is complete, power cycle the MSA and all of its attached hard drive storage
enclosures to activate the new rmware.
For newly installed MSA, do not perform a rmware update until the controller batteries are fully
charged.
1. ObtaintheISOimageforthelatestProLiantFirmwareMaintenanceCDfromthefollowingwebsite:
h
ttp://www.hp.com/support/proliantstorage. Then, burn the image onto a CD using a standard
CD-ROM burning utility. Do not simply copy the ISO le to a blank CD.
NOTE:
If the latest Firmware Maintenance CD does not include the latest-release drive rmware
contained in a Smart Component, the CD can be used in combination with the latest
individual Smart Component package to perform the update.
2. Insert the CD into the CD-ROM drive of the server.
3. Using the navigation window, locate the inventory le on the CD and copy it to a temporary location
on the host. The lename may be similar to InventoryResultsLinux.xml.