Command Line Interface Commands 61
Table 4-36 hostModeOption Parameter Values and Description
hostModeOption Values Description
2 Specify this value when using VERITAS™ Database Edition/Advanced Cluster for Real
Application Clusters or VERITAS™ Cluster Server 4.0 (I/O fencing feature).
6 Specify this value when all of the following conditions are satisfied:
The host connection mode is set to Windows (mode 0C) or Windows Extension (mode 2C).
An Emulex
®
host bus adapter is in use.
A mini-port driver is in use.
The TPRLO parameter for the mini-port driver of the host bus adapter is set to 2.
7 Specify this value when all of the following conditions are satisfied:
The host connection mode is set to Standard (mode 00) or Solaris (mode 09).
You want to let the system automatically recognize the reduction and increase in the number
of devices while a SUN™ host bus adapter is in use.
12 Specify this value when all of the following conditions are satisfied:
The host connection mode is set to HP-UX (mode 03).
You want to prevent devices to which no paths have been defined from creating a device file
when the HP-UX host is connected.
13 Specify this value when you want to get a SIM notification when the number of unsuccessful
connections between ports exceeds a threshold.
14 Specify this value when all of the following conditions are satisfied:
The host connection mode is set to Tru64 (mode 07).
You want to use TruCluster to set up a cluster on both a Continuous Access XP primary and
a secondary volume.
Command execution example: In this example, the CLI command modifies the settings for a port (port number:
16) of a storage subsystem (serial number: 10001, model: XP1024) as follows. The command:
changes the value for the hostmode parameter to Standard, for the port's host storage domain (domain
ID: 0)
changes the topology to Fabric(off), FC-AL
sets the Fibre Channel address to 73
disables LUN security by specifying false
sets the transmission speed of the Fibre Channel to 1
hdvmcli ModifyPort -o "D:\logs\XP1024 ModifyPort.log" serialnum=10001 model=XP1024
port=16 domain=0 hostmode=Standard "topology=Fabric(off), FC-AL" fibreaddr=73
lunsec=false channelspeed=1
Command execution result:
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 Port elements:
An instance of Port
objectID=PORT.HDS9980V.10001.16
portID=16
portType=Fibre
fibreAddress=73
topology=Fabric(off), FC-AL
displayName=CL2-A
lunSecurityEnabled=false
controllerID=5
worldWidePortName=50.06.0E.80.03.3A.99.10
channelSpeed=1
slprNumber=-1
portRole=Target
List of 1 HostStorageDomain elements:
An instance of HostStorageDomain