Compaq Computer Corporation
Houston, Texas
Compaq StorageWorks
UltraSCSI RAID Enclosure
(DS–BA370 Series)
User's Guide
Part Number: EK–BA370–UG. C02/387403–001
September 1998
The DS–BA370 series UltraSCSI RAID rack-mountable enclosure is the
basic building block of UltraSCSI RAID subsystems. This guide and its
related publications comprise the basic documentation set for these
subsystems.
Vista de pagina 0
1 2 3 4 5 6 ... 205 206

Indice de contenidos

Pagina 1 - User's Guide

Compaq Computer CorporationHouston, TexasCompaq StorageWorksUltraSCSI RAID Enclosure(DS–BA370 Series)User's GuidePart Number: EK–BA370–UG. C02/3

Pagina 2

List of Figures x UltraSCSI RAID EnclosureFigure 4–7 Expansion Enclosure Address 3: Shelf and SCSI Bus IDs . . . . . . . . . . . . . . 4–10Figur

Pagina 3 - Table of Contents

Power Verification and Addressing 4–14 UltraSCSI RAID Enclosure 5. Note the enclosure address setting (0, 2, or 3) on the PVA SCSI ID switch (CALL

Pagina 4

Power Verification and Addressing UltraSCSI RAID Enclosure 4–15 3. Pull the PVA extractor latches outward. Push the PVA into the slot until the ext

Pagina 6 - Chapter 7, Storage Devices

UltraSCSI RAID Enclosure 5–1 5Single-Ended I/O ModuleThe single-ended I/O module (see Figure 5–1) performs two functions:• Provides termination fo

Pagina 7 - Chapter 8, Enclosure Blowers

Single-Ended I/O Module 5–2 UltraSCSI RAID Enclosure NoteNot all array controller firmware supports an UltraSCSI RAID subsystem with more than one

Pagina 8

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–3 I/O Module and Expansion Cable Error ConditionsRemoval of an I/O module causes the EMU to repo

Pagina 9

Single-Ended I/O Module 5–4 UltraSCSI RAID Enclosure Controlling the Internal SCSI BusThe I/O module controls the internal SCSI bus in the followi

Pagina 10 - List of Figures

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–5 Controlling the Fault BusThe I/O module controls fault bus operation in the following manner:•

Pagina 11 - List of Tables

Single-Ended I/O Module 5–6 UltraSCSI RAID Enclosure Only when all I/O modules are the same type can an UltraSCSI RAID subsystem function properly

Pagina 12

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–7 See Table 5–1 for possible causes of TERMPOWER problems.Removing an I/O module disconnects the

Pagina 13 - Structure

UltraSCSI RAID Enclosure xiList of TablesTable 1–1 UltraSCSI Subsystems Capacities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 14

Single-Ended I/O Module 5–8 UltraSCSI RAID Enclosure CautionThe Compaq UltraSCSI controller does not support connecting or disconnecting a SCSI bu

Pagina 15 - Documentation Conventions

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–9 Cabling an UltraSCSI SubsystemThis section provides procedures for adding a second and third e

Pagina 16 - Related Documents

Single-Ended I/O Module 5–10 UltraSCSI RAID Enclosure Shutting Down the SubsystemTo protect the data and devices, complete the procedures in Table

Pagina 17

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–11 Table 5–5 Shutting Down the UltraSCSI Subsystem1. Clear the cache module and shut down the ar

Pagina 18

Single-Ended I/O Module 5–12 UltraSCSI RAID Enclosure Cabling a Two-Enclosure SubsystemComplete the procedures in Table 5–6 to connect the master

Pagina 19 - Manufacturer’s Declarations

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–13 5. On the master enclosure I/O module, align the Cable A (CALLOUTA) connector with the left c

Pagina 20 - Acoustic Noise Declarations

Single-Ended I/O Module 5–14 UltraSCSI RAID Enclosure 10. On the expansion enclosure shroud, align the module that has Cable A (CALLOUTA) attached

Pagina 21

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–15 Turning On the SubsystemComplete the procedures in Table 5–7 to turn ON the subsystem.Table 5

Pagina 22

Single-Ended I/O Module 5–16 UltraSCSI RAID Enclosure Cabling a Three-Enclosure SubsystemComplete the procedures in Table 5–8 to connect the maste

Pagina 23 - RAID Enclosure

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–17 Table 5–8 Installing Three-Enclosure Subsystem Cables1. Complete Table 5–5 to shut down the U

Pagina 24

List of Tables xii UltraSCSI RAID EnclosureTable 5–2 UltraSCSI Bus Expansion Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 25 - CXO6264A

Single-Ended I/O Module 5–18 UltraSCSI RAID Enclosure 7. On the master enclosure shroud, align the module that has Cable A (CALLOUTA) attached wit

Pagina 26 - An UltraSCSI Bus Overview

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–19 11. Install a wire tie through the holes on the cable support bracket and around the cable. T

Pagina 27 - Product Description

Single-Ended I/O Module 5–20 UltraSCSI RAID Enclosure 15. On the second expansion enclosure shroud, align the module that has Cable B (CALLOUTB) a

Pagina 28 - 1. SCSI bus

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–21 Replacing an I/O ModuleComplete the procedure in Table 5–9 to remove an I/O module. Complete

Pagina 29 - UltraSCSI RAID Subsystem

Single-Ended I/O Module 5–22 UltraSCSI RAID Enclosure Table 5–10 Installing an I/O Module1. Verify that the I/O module being installing is a model

Pagina 30 - Expansion Enclosure

Single-Ended I/O Module UltraSCSI RAID Enclosure 5–23 Replacing an Expansion CableComplete the procedure in Table 5–11 to remove an expansion cable

Pagina 31 - SCSI Bus Controller

Single-Ended I/O Module 5–24 UltraSCSI RAID Enclosure Table 5–12 Installing an Expansion Cable1. Verify that the expansion cable is the proper typ

Pagina 32 - Enclosure Status

UltraSCSI RAID Enclosure 6–1 6Power DistributionThis chapter describes the UltraSCSI RAID enclosure power distribution to include the following:•

Pagina 33 - For Both Figures

Power Distribution 6–2 UltraSCSI RAID Enclosure NoteProper operation of the controller cache modules requires ECBs. Refer to the array controller

Pagina 34

Power Distribution UltraSCSI RAID Enclosure 6–3 Three configurations exist:• Standard (n+1)• Redundant (n+4)• Optimum (n+4)Standard (n+1)This confi

Pagina 35 - UltraSCSI Bus Expansion

UltraSCSI RAID Enclosure xiii PrefaceThe Compaq StorageWorks UltraSCSI RAID Enclosure (DS–BA370 Series) User’s Guide describes the functions, oper

Pagina 36

Power Distribution 6–4 UltraSCSI RAID Enclosure AC Input BoxThe ac power distribution is provided through the ac input box (see Figure 6–2) to the

Pagina 37 - Enclosure

Power Distribution UltraSCSI RAID Enclosure 6–5 Shelf Power SuppliesEach shelf power supply (see Figure 6–3) converts the incoming ac voltage into

Pagina 38 - UltraSCSI RAID Controllers

Power Distribution 6–6 UltraSCSI RAID Enclosure AC Power BusesAC power distribution to the UltraSCSI shelf power supplies is distributed over two

Pagina 39 - UltraSCSI Nodes

Power Distribution UltraSCSI RAID Enclosure 6–7 Power Distribution ConfigurationsThis section describes the three power configurations for the Ultr

Pagina 40 - CXO5926A

Power Distribution 6–8 UltraSCSI RAID Enclosure Any one of the following power related error conditions will cause this UltraSCSI RAID enclosure t

Pagina 41 - Starting the Subsystem

Power Distribution UltraSCSI RAID Enclosure 6–9 To implement this configuration from an n+1 configuration, order the following additional component

Pagina 42 - Applying Power

Power Distribution 6–10 UltraSCSI RAID Enclosure • Failure of the ac power source for bus B and one power supply on bus A• Failure of the ac power

Pagina 43 - Turning On the Subsystem

Power Distribution UltraSCSI RAID Enclosure 6–11 The green power supply status LED (CALLOUT 2) is ON when the power supply is operating properly. I

Pagina 44 - Shutting Down the Subsystem

Power Distribution 6–12 UltraSCSI RAID Enclosure Replacing a Power SupplyThis section describes how to properly handle power supply SBBs and the p

Pagina 45 - FF the dc power

Power Distribution UltraSCSI RAID Enclosure 6–13 Procedures for Replacing a Power SupplyThe basic procedure for removing and replacing shelf power

Pagina 46 - Turning Off the Subsystem

Preface xiv UltraSCSI RAID Enclosure Chapter 4This chapter describes the power verification and addressing (PVA) assembly operation, functions, use

Pagina 47

Power Distribution 6–14 UltraSCSI RAID Enclosure 4. If there are no expansion enclosures, go to step 5.If there are expansion enclosures, press an

Pagina 48 - Fault Detection

Power Distribution UltraSCSI RAID Enclosure 6–15 9. Press the two mounting tabs together to release the power supply from the shelf. Using both han

Pagina 49 - Enclosure Status Indicators

Power Distribution 6–16 UltraSCSI RAID Enclosure 3. Insert the power supply into the guide slots and push it in until the bezel mounting tabs enga

Pagina 50 - For Figures

Power Distribution UltraSCSI RAID Enclosure 6–17 Replacing an AC Input BoxComplete the procedure in Table 6–5 to remove an ac input box. Complete t

Pagina 51 - LED is O

Power Distribution 6–18 UltraSCSI RAID Enclosure 4. Disconnect the ac power cord (CALLOUT4) from the ac input box (CALLOUT1).5. Loosen the two ret

Pagina 52 - ALLOUT 2) is ON when the

Power Distribution UltraSCSI RAID Enclosure 6–19 3. Align the ac input box (CALLOUT1) with either slot A or slot B in the lower left or lower right

Pagina 54 - N or FLASHING indicates

UltraSCSI RAID Enclosure 7–1 7Storage DevicesThis chapter describes the procedures for handling, addressing, identifying, and replacing disk drive

Pagina 55 - CXO6303A

Storage Devices 7–2 UltraSCSI RAID Enclosure Identifying a Storage DeviceTo determine the model number of a storage device (disk drive SBB), look

Pagina 56 - ALLOUT 2) and external

Storage Devices UltraSCSI RAID Enclosure 7–3 Figure 7–3 Typical Drive SBB Bezel LabelDisk Drive SBB Device AddressingDetermining the disk drive SBB

Pagina 57 - Environmental Monitoring

Preface UltraSCSI RAID Enclosure xv Documentation ConventionsTable 1 describes the conventions for this publication:Table 1 Documentation Conventio

Pagina 58

Storage Devices 7–4 UltraSCSI RAID Enclosure Disk Drive SBB Status ReportingThe array controller monitors the status of the disk drive SBBs. If a

Pagina 59 - FF the enclosure

Storage Devices UltraSCSI RAID Enclosure 7–5 See Table 7–1 for definitions of the LED displays.Table 7–1 Disk Drive Status LED DisplaysLED DisplayD

Pagina 60 - I/O Module Status

Storage Devices 7–6 UltraSCSI RAID Enclosure Guidelines for Replacing a Disk Drive SBBThis section describes the SBB connector and items to consid

Pagina 61 - FF and initiates a fault

Storage Devices UltraSCSI RAID Enclosure 7–7 Prerequisites for Replacing a Disk Drive SBBReplacing a disk drive SBB is a relatively simple procedur

Pagina 62

Storage Devices 7–8 UltraSCSI RAID Enclosure Hot SwapWhen performing a hot swap, power and data are present on the disk drive SBB backplane connec

Pagina 63 - Configuring the EMU

Storage Devices UltraSCSI RAID Enclosure 7–9 Replacing a Disk Drive SBBThis section describes how to properly handle disk drive SBBs and the proced

Pagina 64 - EMU Firmware

Storage Devices 7–10 UltraSCSI RAID Enclosure Procedures for Replacing a Disk Drive SBBComplete the procedure in Table 7–3 to remove a disk drive

Pagina 65 - EMU Firmware Version 1.2

Storage Devices UltraSCSI RAID Enclosure 7–11 6. If there are no expansion enclosures, go to step 7.If there are expansion enclosures, turn OFF all

Pagina 66

Storage Devices 7–12 UltraSCSI RAID Enclosure Table 7–4 Installing a Disk Drive SBB1. Verify that the disk drive SBB is the correct model and fill

Pagina 67 - Environmental Monitoring Unit

Storage Devices UltraSCSI RAID Enclosure 7–13 6. If performing a cold swap, determine if there are expansion enclosures. If there are no expansion

Pagina 68

Preface xvi UltraSCSI RAID Enclosure Related DocumentsTable 2 lists publications that contain additional information about the UltraSCSI RAID subsy

Pagina 69

Storage Devices 7–14 UltraSCSI RAID Enclosure 11. Starting at the left end, install all the disk drive SBB devices in shelf 4 (devices 19 through

Pagina 70 - EMU Status Reporting

UltraSCSI RAID Enclosure 8–1 8Enclosure BlowersEnsuring proper UltraSCSI RAID enclosure operation requires establishing and maintaining the proper

Pagina 71 - FF until one of the

Enclosure Blowers 8–2 UltraSCSI RAID Enclosure Figure 8–1 Enclosure Blower Assembly LocationsEnclosure temperature sensors (see Chapter 3) detect

Pagina 72 - EMU Status LEDs

Enclosure Blowers UltraSCSI RAID Enclosure 8–3 • If a blower error condition is caused by only one defective blower per blower bank (see Figure 8–1

Pagina 73

Enclosure Blowers 8–4 UltraSCSI RAID Enclosure CautionThe only StorageWorks dual-speed blower that is compatible with this UltraSCSI RAID enclosur

Pagina 74 - N. Refer to Figure 3–5 as

Enclosure Blowers UltraSCSI RAID Enclosure 8–5 CautionOperating an UltraSCSI enclosure with a blower removed significantly changes the air flow pat

Pagina 75

Enclosure Blowers 8–6 UltraSCSI RAID Enclosure Table 8–2 Installing a Blower1. Verify that the blower is a model DS–BA35X–MK.2. Orient the replace

Pagina 76 - CXO6546A

UltraSCSI RAID Enclosure A–1 Appendix AUltraSCSI EnclosureSpecificationsThis appendix defines the physical, electrical, and environmental specific

Pagina 77 - LASHING alarm control

UltraSCSI Enclosure Specifications A–2 UltraSCSI RAID Enclosure NoteThe operating and servicing physical specifications as well as the electrical s

Pagina 78 - CXO6598A

UltraSCSI Enclosure Specifications UltraSCSI RAID Enclosure A–3 Operating EnvironmentsTable A–1, Table A–2, and Table A–3 provide the environmental

Pagina 79 - CXO5762A

Preface UltraSCSI RAID Enclosure xvii Operating System Specific Release NotesSee system-specific “Getting Started” manualImproving UltraSCSI RAID S

Pagina 80 - CXO5763A

UltraSCSI Enclosure Specifications A–4 UltraSCSI RAID Enclosure Table A–3 Shipping EnvironmentCondition SpecificationTemperature –40°C to +66°C (–4

Pagina 81

UltraSCSI Enclosure Specifications UltraSCSI RAID Enclosure A–5 SBB Thermal StabilizationFor proper operation upon initial power application, maint

Pagina 83 - CXO5773A

UltraSCSI RAID Enclosure B–1 Appendix BAssembling an UltraSCSIRAID SubsystemAssembling an UltraSCSI RAID subsystem (see Figure B–1) requires seque

Pagina 84 - Replacing an EMU

Assembling an UltraSCSI RAID Subsystem B–2 UltraSCSI RAID Enclosure Installation SequenceThe basic installation sequence is the same for all UltraS

Pagina 85 - CXO5754B

Assembling an UltraSCSI RAID Subsystem UltraSCSI RAID Enclosure B–3 1. Mount an empty UltraSCSI RAID enclosure in the data center cabinet using cab

Pagina 86 - CXO5820A

Assembling an UltraSCSI RAID Subsystem B–4 UltraSCSI RAID Enclosure Installing the I/O Modules and Expansion CablesSix single-ended I/O modules (DS

Pagina 87 - CXO-5737A

Assembling an UltraSCSI RAID Subsystem UltraSCSI RAID Enclosure B–5 Installing Array Controllers and Cache ModulesThe master enclosure contains the

Pagina 88

Assembling an UltraSCSI RAID Subsystem B–6 UltraSCSI RAID Enclosure Table B–1 describes the mechanical procedures for installing array controllers

Pagina 89 - Functions

Assembling an UltraSCSI RAID Subsystem UltraSCSI RAID Enclosure B–7 2. Insert the array controller into the Controller A slot and push it in until

Pagina 91

Assembling an UltraSCSI RAID Subsystem B–8 UltraSCSI RAID Enclosure 7. If a second array controller and cache module set is required, repeat steps

Pagina 92 - +4.7 V dc +11.4 V dc

Assembling an UltraSCSI RAID Subsystem UltraSCSI RAID Enclosure B–9 Installing the Power SystemThe ac input boxes and shelf power supplies comprise

Pagina 93 - Setting the Enclosure Address

Assembling an UltraSCSI RAID Subsystem B–10 UltraSCSI RAID Enclosure Connecting Subsystem CablesCabinet user documentation describes the cable rout

Pagina 94 - CXO-4840A-MC

UltraSCSI RAID Enclosure C–1 Appendix CInstalling EMU MicrocodeThe microcode resident in the EMU memory controls all the UltraSCSI RAID enclosure

Pagina 95

Installing EMU Microcode C–2 UltraSCSI RAID Enclosure PrerequisitesThe following items are required to upgrade the EMU microcode using the EMU UART

Pagina 96

Installing EMU Microcode UltraSCSI RAID Enclosure C–3 5. Use the PROCOMM PLUS Setup Utility to establish the following parameters for modem and pro

Pagina 97

Installing EMU Microcode C–4 UltraSCSI RAID Enclosure Preparing the EMUComplete the procedure in Table C–2 to prepare the EMU for loading the micro

Pagina 98 - Replacing a PVA

Installing EMU Microcode UltraSCSI RAID Enclosure C–5 Table C–4 Typical PC Monitor DisplayDisplay Text CommentsSW 370 EMU (ROM) Version V01.02Copyr

Pagina 99

Installing EMU Microcode C–6 UltraSCSI RAID Enclosure Restarting the ControllerComplete the procedure in Table C–5 to restart the controller after

Pagina 100 - Table 4–7 Installing a PVA

UltraSCSI RAID Enclosure Glossary–1 GlossaryThis glossary defines terms pertaining to the DS-BA370 series UltraSCSI RAID enclosure. It is not a co

Pagina 101 - CXO5488B

UltraSCSI RAID Enclosure xix Manufacturer’s DeclarationsThis section discusses electromagnetic compatibility and accoustic noise declarations.Elec

Pagina 102

Glossary Glossary–2 UltraSCSI RAID Enclosure ambient air temperatureThe temperature of the air surrounding the cabinet, enclosure, shelf, or SBB t

Pagina 103 - Single-Ended I/O Module

Glossary UltraSCSI RAID Enclosure Glossary–3 CautionThe device transceiver type (single-ended or differential) must match the bus segment type. Dev

Pagina 104 - Single-Ended I/O Module

Glossary Glossary–4 UltraSCSI RAID Enclosure certified deviceA storage device tested in a specific configuration and found to be in compliance wit

Pagina 105 - FF the enclosure power

Glossary UltraSCSI RAID Enclosure Glossary–5 converterSee SCSI bus signal converter.data center cabinetThe largest of the StorageWorks cabinets, su

Pagina 106

Glossary Glossary–6 UltraSCSI RAID Enclosure ECBExternal cache battery. A device that provides backup power to a cache module for sustaining memor

Pagina 107 - FF without

Glossary UltraSCSI RAID Enclosure Glossary–7 expansion enclosureAn UltraSCSI RAID enclosure connected to the master enclosure with UltraSCSI bus ca

Pagina 108 - N during normal operation

Glossary Glossary–8 UltraSCSI RAID Enclosure Federal Communications CommissionSee FCC.filler panelA panel used to cover open unused areas in cabin

Pagina 109

Glossary UltraSCSI RAID Enclosure Glossary–9 HSOFHierarchical Storage Operating Firmware. HS-family controller software contained on a removable RO

Pagina 110 - CXO5819A

Glossary Glossary–10 UltraSCSI RAID Enclosure master enclosureThe UltraSCSI RAID enclosure that includes the HSZ series controllers and cache modu

Pagina 111

Glossary UltraSCSI RAID Enclosure Glossary–11 physical busTwo SCSI terminators separated by cables, connectors, and backplane circuitry.port(1) A l

Pagina 112 - CXO5702A

September 1998While Compaq Computer Corporation believes the information included in this publication is correct as of the date of publication, i

Pagina 113

Manufacturer’s Declarations xx UltraSCSI RAID Enclosure Acoustic Noise DeclarationsCompaq® declares that the acoustic values of this product are as

Pagina 114 - CXO5816A

Glossary Glossary–12 UltraSCSI RAID Enclosure redundant power supply configurationA capability of StorageWorks cabinet and shelves to ensure that

Pagina 115

Glossary UltraSCSI RAID Enclosure Glossary–13 SCSI deviceA host computer adapter, a peripheral array controller or an intelligent peripheral that c

Pagina 116

Glossary Glossary–14 UltraSCSI RAID Enclosure See also spin-up.spin-upA process that begins when power is applied to a storage device, and ends wh

Pagina 117 - N the subsystem

Glossary UltraSCSI RAID Enclosure Glossary–15 StorageWorks building blockSee SBB.supported device(1) A device that has been fully evaluated in an “

Pagina 118

Glossary Glossary–16 UltraSCSI RAID Enclosure See also STERMPOWER.topologyThe physical arrangement and relationship of interconnected nodes and SC

Pagina 119 - CXO5854B

Glossary UltraSCSI RAID Enclosure Glossary–17 UltraSCSI RAID subsystemOne or more UltraSCSI RAID enclosures mounted in either a pedestal or a cabin

Pagina 121

Manufacturer’s Declarations UltraSCSI RAID Enclosure xxi Table 2Schallemissionswerte – Werteangaben nach ISO 9296 und ISO 7779/DIN EN27779GerätScha

Pagina 123 - Replacing an I/O Module

UltraSCSI RAID Enclosure 1–1 1Introducing the UltraSCSIRAID EnclosureThe Compaq StorageWorks™ UltraSCSI RAID (redundant array of independent disks

Pagina 124

Introducing the UltraSCSI RAID Enclosure 1–2 UltraSCSI RAID Enclosure This enclosure cannot function until:1. It is installed in an UltraSCSI data

Pagina 125 - Replacing an Expansion Cable

Introducing the UltraSCSI RAID Enclosure UltraSCSI RAID Enclosure 1–3 Figure 1–2 Typical DS–BA370 Applications010010010010010010CXO6264A

Pagina 126

Introducing the UltraSCSI RAID Enclosure 1–4 UltraSCSI RAID Enclosure An UltraSCSI Bus OverviewUltraSCSI was developed by Digital Equipment Corpor

Pagina 127 - Power Distribution

Introducing the UltraSCSI RAID Enclosure UltraSCSI RAID Enclosure 1–5 Product DescriptionThe UltraSCSI enclosure is a rack-mountable storage subsys

Pagina 128 - Power System Overview

Introducing the UltraSCSI RAID Enclosure 1–6 UltraSCSI RAID Enclosure Expansion enclosures have filler panels installed in the controller and cach

Pagina 129 - AC Power Source

Introducing the UltraSCSI RAID Enclosure UltraSCSI RAID Enclosure 1–7 •EMU•PVA• UltraSCSI bus array controllers and cache modules• Disk drives• I/O

Pagina 130 - AC Input Box

UltraSCSI RAID Enclosure iiiTable of ContentsPreface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 131 - Shelf Power Supplies

Introducing the UltraSCSI RAID Enclosure 1–8 UltraSCSI RAID Enclosure PVAEach PVA functions only with its host enclosure and EMU. There is no mast

Pagina 132 - ALLOUT 1), Compaq recommends

Introducing the UltraSCSI RAID Enclosure UltraSCSI RAID Enclosure 1–9 2 — Establishing SCSI bus device addresses 8, 9, 10, and 113 — Establishing S

Pagina 133

Introducing the UltraSCSI RAID Enclosure 1–10 UltraSCSI RAID Enclosure NoteDS–HSx70 series array controllers require DS–HSx70 series cache modules

Pagina 134 - Configurations

Introducing the UltraSCSI RAID Enclosure UltraSCSI RAID Enclosure 1–11 OptionsThe following sections describe the UltraSCSI RAID subsystem user sel

Pagina 135

Introducing the UltraSCSI RAID Enclosure 1–12 UltraSCSI RAID Enclosure Redundant Power Supply ConfigurationAdding three power supplies and a secon

Pagina 136 - Error Condition Reporting

Introducing the UltraSCSI RAID Enclosure UltraSCSI RAID Enclosure 1–13 Compaq recommends using this configuration to eliminate all single points of

Pagina 138 - Replacing a Power Supply

UltraSCSI RAID Enclosure 2–1 2Operating the UltraSCSIEnclosureSetting up an UltraSCSI RAID subsystem for operation involves implementing the proce

Pagina 139

Operating the UltraSCSI Enclosure 2–2 UltraSCSI RAID Enclosure • The following devices use a SCSI bus address (ID) and are SCSI bus nodes:— Adapte

Pagina 140 - Power Distribution

Operating the UltraSCSI Enclosure UltraSCSI RAID Enclosure 2–3 • Compaq UltraSCSI array controllers support FAST 10 (20 MB/s) 16-bit (wide) disk dr

Pagina 141

Table of Contents iv UltraSCSI RAID EnclosureChapter 2, Operating the UltraSCSI EnclosureUltraSCSI Configuration Rules . . . . . . . . . . . . . . .

Pagina 142

Operating the UltraSCSI Enclosure 2–4 UltraSCSI RAID Enclosure UltraSCSI EnclosuresThe following configuration rules apply to UltraSCSI RAID subsy

Pagina 143 - Replacing an AC Input Box

Operating the UltraSCSI Enclosure UltraSCSI RAID Enclosure 2–5 See Table 2–1 for the Compaq-supported PVA SCSI ID switch settings.Starting the Subs

Pagina 144

Operating the UltraSCSI Enclosure 2–6 UltraSCSI RAID Enclosure Applying PowerInitial power application is a matter of turning on the ac input boxe

Pagina 145

Operating the UltraSCSI Enclosure UltraSCSI RAID Enclosure 2–7 Turning On the SubsystemAfter completing subsystem assembly, expansion, or movement

Pagina 146

Operating the UltraSCSI Enclosure 2–8 UltraSCSI RAID Enclosure Shutting Down the SubsystemShutting down the subsystem involves:• Clearing the cach

Pagina 147 - Storage Devices

Operating the UltraSCSI Enclosure UltraSCSI RAID Enclosure 2–9 Using Standby Power ModeComplete the procedure in Table 2–3 to turn OFF the dc power

Pagina 148 - Identifying a Storage Device

Operating the UltraSCSI Enclosure 2–10 UltraSCSI RAID Enclosure Turning Off the SubsystemAdding enclosures or moving the subsystem might require r

Pagina 149

Operating the UltraSCSI Enclosure UltraSCSI RAID Enclosure 2–11 Table 2–5 Turning Off the Subsystem Power1. Clear the cache module and shut down th

Pagina 150 - Storage Devices

Operating the UltraSCSI Enclosure 2–12 UltraSCSI RAID Enclosure Fault DetectionFault detection involves identifying errors and providing an indica

Pagina 151

Operating the UltraSCSI Enclosure UltraSCSI RAID Enclosure 2–13 For a detailed description of status LEDs, and specific error conditions, see the a

Pagina 152 - The SBB Connector

Table of Contents UltraSCSI RAID Enclosure v Maintenance Terminal Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 153

Operating the UltraSCSI Enclosure 2–14 UltraSCSI RAID Enclosure CALLOUT 1 is the system OK LED and is green. Callout 2 is the system fault L

Pagina 154 - LASHING

Operating the UltraSCSI Enclosure UltraSCSI RAID Enclosure 2–15 Table 2–7 Enclosure Status LED DisplaysEnclosure TypeDescription and Possible Corre

Pagina 155 - Replacing a Disk Drive SBB

Operating the UltraSCSI Enclosure 2–16 UltraSCSI RAID Enclosure SBB Shelf Status IndicatorsSBB shelf status indicators are provided by shelf power

Pagina 156

Operating the UltraSCSI Enclosure UltraSCSI RAID Enclosure 2–17 Removal of a disk drive SBB device is automatically sensed by the array controller.

Pagina 157 - CXO-5338A-MC

Operating the UltraSCSI Enclosure 2–18 UltraSCSI RAID Enclosure Controller Shelf Status IndicatorsController shelf status indicators are provided

Pagina 158 - CXO-4562A-MC

Operating the UltraSCSI Enclosure UltraSCSI RAID Enclosure 2–19 EMU Status LEDsThe EMU status LEDs (see Figure 2–8) have multiple functions (see Ch

Pagina 159

Operating the UltraSCSI Enclosure 2–20 UltraSCSI RAID Enclosure I/O Module LEDsEach I/O module (see Figure 2–10) has two green status LEDs that di

Pagina 160

UltraSCSI RAID Enclosure 3–1 3Environmental MonitoringUnitThe primary function of the EMU (Figure 3–1) is to monitor, process, report, and display

Pagina 161 - Enclosure Blowers

Environmental Monitoring Unit 3–2 UltraSCSI RAID Enclosure Product DescriptionThe EMU detects enclosure error conditions and configuration faults,

Pagina 162 - Enclosure Blowers

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–3 CautionSome array controllers bypass the standby power mode functionality from the PVA s

Pagina 163 - Function and Operation

Table of Contents vi UltraSCSI RAID EnclosureError Reporting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 164 - FF the dc power distribution

Environmental Monitoring Unit 3–4 UltraSCSI RAID Enclosure I/O Module StatusThe EMU verifies that the six I/O modules are present, properly instal

Pagina 165 - CXO5753B

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–5 EMU Front PanelThe EMU user interface controls, connectors, and LED displays are on the

Pagina 166

Environmental Monitoring Unit 3–6 UltraSCSI RAID Enclosure Temperature Fault LEDIf either the intake or exhaust air temperature exceeds user-defin

Pagina 167 - Specifications

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–7 Configuring the EMUConfiguring the EMU requires connecting the EMU-EMU communications bu

Pagina 168 - CXO5797A

Environmental Monitoring Unit 3–8 UltraSCSI RAID Enclosure EMU FirmwareEMU firmware allows the user to use CLI commands to establish limits for EM

Pagina 169 - Operating Environments

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–9 CautionFor EMU firmware versions 1.0 and 1.1, the command set emu sensor_n_setpoint=defa

Pagina 170 - Altitude 4900 m (16,000 ft)

Environmental Monitoring Unit 3–10 UltraSCSI RAID Enclosure NoteDefault temperature settings for EMU firmware version 1.2 are:• Sensors 1 and 2 —

Pagina 171 - SBB Thermal Stabilization

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–11 NoteFor detailed instructions about using the set emu commands, refer to the array cont

Pagina 172

Environmental Monitoring Unit 3–12 UltraSCSI RAID Enclosure Setting the Blower Speed ControlUltraSCSI enclosure blowers normally operate at low-sp

Pagina 173 - Appendix B

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–13 NoteFor detailed instructions about using the set emu commands, refer to the array cont

Pagina 174 - Installation Sequence

Table of Contents UltraSCSI RAID Enclosure vii Guidelines for Replacing a Disk Drive SBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 175 - Installing the PVA

Environmental Monitoring Unit 3–14 UltraSCSI RAID Enclosure • Starts the EMU timer if: (1) all blowers in a shelf bank are defective, or (2) a blo

Pagina 176

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–15 •Fault conditions—involves a subsystem configuration problem, such as a Boot ROM checks

Pagina 177 - CXO5798A

Environmental Monitoring Unit 3–16 UltraSCSI RAID Enclosure • The error condition still exists after 1 hour has passed. This situation causes the

Pagina 178 - 3) in the

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–17 Monitoring Power Supply OperationsEven with four operational power supplies, it is poss

Pagina 179 - (Continued)

Environmental Monitoring Unit 3–18 UltraSCSI RAID Enclosure Error Condition ReportingEMU status LEDs identify system (enclosure) status, power sta

Pagina 180

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–19 Nonoperational EnclosureProbable Cause 1—Either +5 V dc or 12 V dc out of range. Observ

Pagina 181 - Installing the Power System

Environmental Monitoring Unit 3–20 UltraSCSI RAID Enclosure Configuration Error (Example 1)Probable Cause 1—Configuration error. See the Configura

Pagina 182 - Configuring the Subsystem

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–21 Configuration Fault Code ReportingThe system fault, temperature, power, and blower LEDs

Pagina 183 - Appendix C

Environmental Monitoring Unit 3–22 UltraSCSI RAID Enclosure Each time the alarm control switch is momentarily pressed, the EMU initiates the follo

Pagina 184 - Preliminary Procedure

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–23 Fault Code 02Both microcode images are bad.1. Load microcode image into the EMU from a

Pagina 185 - Installing EMU Microcode

Table of Contents viii UltraSCSI RAID EnclosureLoading the Microcode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 186 - Loading the Microcode

Environmental Monitoring Unit 3–24 UltraSCSI RAID Enclosure Fault Code 04Master EMU cannot communicate with expansion EMU.1. Ensure PVA SCSI ID sw

Pagina 187

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–25 Fault Code 07Invalid configuration.Requires an array controller-specific action (see th

Pagina 188 - Restarting the Controller

Environmental Monitoring Unit 3–26 UltraSCSI RAID Enclosure Fault Code 0ANo PVA is installed.Install a PVA.Fault Code 0BController fault.Requires

Pagina 189 - Glossary

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–27 Fault Code 0EEMU memory test failed.Replace the EMU.Fault Code 0FLess than four operati

Pagina 190 - Glossary

Environmental Monitoring Unit 3–28 UltraSCSI RAID Enclosure Replacing an EMUComplete the procedure in Table 3–9 to remove an EMU and complete the

Pagina 191

Environmental Monitoring Unit UltraSCSI RAID Enclosure 3–29 6. Pull the EMU extractor latches outward and remove the EMU.Table 3–10 Installing an E

Pagina 192

Environmental Monitoring Unit 3–30 UltraSCSI RAID Enclosure 3. Pull the EMU extractor latches outward. Push the EMU into the slot until the extrac

Pagina 193

UltraSCSI RAID Enclosure 4–1 4Power Verification andAddressingAn enclosure’s PVA assembly (see Figure 4–1) and associated EMU monitors the status

Pagina 194

Power Verification and Addressing 4–2 UltraSCSI RAID Enclosure The PVA and EMU mount next to each other in the enclosure—the EMU (CALLOUT 1) is on

Pagina 195

Power Verification and Addressing UltraSCSI RAID Enclosure 4–3 The PVA has two status indicators:• A green power status LED that is part of the sta

Pagina 196

UltraSCSI RAID Enclosure ixList of FiguresFigure 1–1 DS–BA370 Series UltraSCSI Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 197

Power Verification and Addressing 4–4 UltraSCSI RAID Enclosure This action—removing power from the enclosure—duplicates an EMU function and ensure

Pagina 198

Power Verification and Addressing UltraSCSI RAID Enclosure 4–5 Figure 4–4 Master Enclosure Device IDsUse the PVA SCSI ID switch to establish SCSI b

Pagina 199

Power Verification and Addressing 4–6 UltraSCSI RAID Enclosure Monitoring Power Supply OperationsEven with four operational power supplies, it is

Pagina 200

Power Verification and Addressing UltraSCSI RAID Enclosure 4–7 Setting the Enclosure AddressThe PVA SCSI ID switch establishes the SCSI bus address

Pagina 201

Power Verification and Addressing 4–8 UltraSCSI RAID Enclosure Master Enclosure AddressThe master enclosure PVA SCSI ID switch setting is always 0

Pagina 202

Power Verification and Addressing UltraSCSI RAID Enclosure 4–9 Expansion Enclosure AddressesCompaq supports only PVA SCSI ID switch settings of 2 (

Pagina 203

Power Verification and Addressing 4–10 UltraSCSI RAID Enclosure Figure 4–7 Expansion Enclosure Address 3: Shelf and SCSI Bus IDsImplementing the S

Pagina 204

Power Verification and Addressing UltraSCSI RAID Enclosure 4–11 Table 4–4 Turning Off the DC Power Distribution1. Clear the cache module and shut d

Pagina 205

Power Verification and Addressing 4–12 UltraSCSI RAID Enclosure Replacing a PVAComplete the procedures in Table 4–6 to remove a PVA. Complete the

Pagina 206

Power Verification and Addressing UltraSCSI RAID Enclosure 4–13 2. If there are no expansion enclosures, go to step 3.If there are expansion enclos