Understanding Errors and Troubleshooting
Understanding Error States
Chapter 44-12
Fibre Channel
interface failed
Fibre Channel interface failed
power-up test. (Usually due to
problems on the SCSI bus, such
as an LVDS drive or terminator
on an HVDS bus, etc.)
• Verify that proper SCSI
terminators and/or tape drives
are attached to the Fibre
Channel interface, and then
reboot the library.
• Power cycle the library.
• Contact your service
representative.
Power supply
fault
Library detected one or more
redundant power supplies in a
failed condition.
• Determine which power supply
has failed. See page 4-27 for
LED status information.
• Contact your service
representative to replace the
power supply.
Table 4-1 Partial Availability Conditions
Library Status Cause Solution