9 Array mapping
To correctly map the ACP and CHIP pairs, see the following tables for the respective a rray:
Table 2 lists 1 AC P pair for disk array XP48/128.
NOTE:
The cards are lettered A-M, omitting I.
Table 2 XP48/128 (1 ACP Pair)
B, L
ACP Pair 1 ACP B = 0; L = 4
C, G CHIP Pair 1
Chip C = 0; G = 4
D, J
CHIP Pair 2
Chip D = 1; J = 5
F, K
CHIP Pair 3
Chip F = 2; K = 6
Table 3 lists the 2 ACP pairs for di sk array XP 48/128.
NOTE:
The cards are lettered A-M, omitting I.
Table 3 XP 48/128 (2 ACP Pairs)
B, L
ACP Pair 1 ACP B = 0; L = 4
F, K
ACP Pair 2 ACP F = 1; K = 5
C, G CHIP Pair 1
Chip C = 0; G = 4
D, J
CHIP Pair 2
Chip D = 1; J = 5
Table 4 lists the ACP and CHIP pairs for XP256/512/1024.
NOTE:
The cards are lettered A-Z, omitting I and O; with 12 cards on the back (A-M) and 12 on the front (N-Z).
HP StorageWorks Performance Advisor XP Software command-line user interface user guide