Hp StorageWorks XP Remote Web Console Software Manual de usuario

Busca en linea o descarga Manual de usuario para Almacenamiento Hp StorageWorks XP Remote Web Console Software. HP StorageWorks XP Remote Web Console Software User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 98
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
HP StorageWorks
LUN Configuration and Security Manager XP
user guide
for the XP128/XP1024
Part number: T1614-96003
Second edition: December 2005
Vista de pagina 0
1 2 3 4 5 6 ... 97 98

Indice de contenidos

Pagina 1 - HP StorageWorks

HP StorageWorksLUN Configuration and Security Manager XP user guidefor the XP128/XP1024Part number: T1614-96003Second edition: December 2005

Pagina 2

10Table 1 Recommended and minimum firmware versionsRelated documentationIn addition to this guide, please refer to other documents for this product:•

Pagina 3 - Contents

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 11Collect the following information before calling:• Technical support regis

Pagina 5

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 131 LUN Manager for the XP128/XP1024You can connect XP arrays to open system

Pagina 6

14 LUN Manager for the XP128/XP1024• Up to 255 hosts can be included in all the host groups for one Fibre Channel port• Up to 16 hosts can be included

Pagina 7

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 15In Figure 1, the LUs associated with the hg-lnx domain are addressed by nu

Pagina 8

16 LUN Manager for the XP128/XP1024LU 00:00 (LUN 00). One path comes from the CL1-N port and the other path comes from the CL1-Q port. Thanks to this

Pagina 9 - About this guide

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 17load balancing among processors, there is no reason not to use both ports

Pagina 10 - HP technical support

18 LUN Manager for the XP128/XP1024Figure 5 Host group example 2LUN Manager can define paths between a single host and multiple LUs. In Figure 5, each

Pagina 11 - Subscription service

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 19LUN SecurityTo protect data from unauthorized access, apply security polic

Pagina 12

Legal and notice information© Copyright 2005 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required f

Pagina 13 - LU paths

20 LUN Manager for the XP128/XP1024In Figure 6, the hosts in the hpux-G01 group can access LUN0 and LUN1 associated with the same host group, but cann

Pagina 14 - Host storage domains

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 21If you want to use a LUSE volume as a command device, you must specify onl

Pagina 15

22 LUN Manager for the XP128/XP1024Data transfer speed for Fibre Channel portsAs disk array operation continues, you may notice that a larger amount o

Pagina 16 - 16-Port FC/CA CHIP product

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 23If high-speed (2 port) mode is applied to a four-port channel adapter boar

Pagina 17 - Host groups

24 LUN Manager for the XP128/XP1024• iSCSI name: (Mandatory). You must assign iSCSI names to iSCSI ports. iSCSI names are used to uniquely identify ea

Pagina 18 - Host modes

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 25responds to the ping command, the host and the XP128/XP1024 can communicat

Pagina 19 - LUN Security

26 LUN Manager for the XP128/XP1024Host authenticationWhen a host attempts to connect to the disk array, the connection results of the host’s authenti

Pagina 20 - RAID Manager command devices

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 27CAUTION: If a host uses Microsoft iSCSI Initiator and is configured for po

Pagina 21 - Fibre Channel port attributes

28 LUN Manager for the XP128/XP1024The user information of Host C is not registered on port 1. When Host C tries to connect to the disk array, authent

Pagina 22

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 29LU Path treeThe LU Path tree on the upper left of the LUN Manager tab list

Pagina 23 - ®, or HP-UX 11i

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 3About this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 24 - ® iSNS Server as the iSNS

30 LUN Manager for the XP128/XP1024The following are the NAS port icons used in the LU Path tree:Table 7 NAS port icons for LUN Manager operationsIcon

Pagina 25

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 31When you double-click a NAS port, the following host groups appear:• NAS-S

Pagina 26 - Host authentication

32 LUN Manager for the XP128/XP1024LU Path tableOn the right side of the LU Path tree is a table that displays LU Path information about the hosts in

Pagina 27

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 33The tables contain the following information:• A list of ports• Host Group

Pagina 28 - LUN Manager operations

34 LUN Manager for the XP128/XP10242. Create host groups (”Creating host groups” on page 34).3. Register hosts in host groups (”Registering hosts in h

Pagina 29 - NAS folder

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 357. In the LUN Manager main pane, click Apply. A confirmation message appea

Pagina 30 - Icon Status

36 LUN Manager for the XP128/XP10242. If the desired host has never been connected via a cable to another port in the disk array, skip to step 8.3. In

Pagina 31

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 37Figure 18 Add New iSCSI Name dialog box (when registering a host that has

Pagina 32 - WWN or iSCSI name table

38 LUN Manager for the XP128/XP10242. In the LU Path table, select one or more LUNs to which LDEVs are assigned (If an LDEV is assigned to a LUN, the

Pagina 33 - Defining LU paths

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 391. In the LU Path tree on the LUN Manager main pane, right-click a host gr

Pagina 34 - Creating host groups

4Changing or viewing LU path settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Deleting LU path

Pagina 35

40 LUN Manager for the XP128/XP1024\Figure 21 Change iSCSI Name & Nickname dialog boxIf the selected WWN or iSCSI name is not registered in a host

Pagina 36

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 41Deleting HBAs from host groupsNOTE: You cannot perform this operation on h

Pagina 37 - Deleting LU paths

42 LUN Manager for the XP128/XP1024Copying paths from one Fibre Channel or iSCSI port to anotherCAUTION: Before performing the following steps, see ”R

Pagina 38 - Deleting host groups

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 43Copying paths from a Fibre Channel or iSCSI port to a NAS portCAUTION: Bef

Pagina 39

44 LUN Manager for the XP128/XP1024Viewing alternate paths1. From the LUN Manager main pane, do one of the following:• In the LU Path table, select a

Pagina 40

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 45NOTE: If the shortcut menu includes the item Command Device: ON->OFF, t

Pagina 41 - Defining alternate paths

46 LUN Manager for the XP128/XP1024NOTE: High-speed (2 port) mode is available only if the XP disk array has firmware version 21.06.22 or later instal

Pagina 42

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 47• Attribute: Indicates the port attribute (always set to Target for iSCSI

Pagina 43

48 LUN Manager for the XP128/XP10243. Click OK.4. Click Apply. A confirmation message appears. 5. Click OK. The settings are applied to the disk array

Pagina 44 - Deleting WWNs

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 492. Select an iSCSI port from the Subsystem Port Name. The IP address of th

Pagina 45 - Port Operations

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 5LUSE rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 46 - Port table

50 LUN Manager for the XP128/XP10242. Click the User Authentication tab. The User Authentication pane appears.Figure 24 User Authentication tab (LUN M

Pagina 47 - Change Port Mode box

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 51The table contains the following columns:• iSCSI Name: Displays iSCSI name

Pagina 48 - Configuring iSCSI Ports

52 LUN Manager for the XP128/XP1024b. Right-click any point in the User Information (Host) table.3. Select Add New User Information (Host) from the sh

Pagina 49 - (iSCSI environment only)

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 53Changing user information of hostsYou can change the registered user name

Pagina 50 - User Authentication tab

54 LUN Manager for the XP128/XP10242. Right-click any point in the User Information (Port) table and select Specify User Information (Port). The Speci

Pagina 51 - User Information (Port) table

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 55Table 15 shows the relationship between the combinations of port settings

Pagina 52

56 LUN Manager for the XP128/XP1024Restrictions on port operationsSetting the LUN Security Switch OFFWith active I/O on portInvalid operation Permitte

Pagina 53

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 57Changing PCB mode With active I/O on LUN Not permittedWith no active I/O o

Pagina 54

58 LUN Manager for the XP128/XP1024

Pagina 55 - Operational restrictions

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 592 Volume Management for the XP128/XP1024Use Volume Management to perform t

Pagina 56

610 LUN Manager main pane. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2811 NAS fold

Pagina 57 - Activity

60 Volume Management for the XP128/XP1024For example, if you combine LDEV00, LDEV03 and LDEV05 into LUSE 1, LDEV02 and LDEV04 into LUSE 2, and LDEV06

Pagina 58

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 61• Install CV: Creates custom volumes from free space.• Make Volume: Conver

Pagina 59 - LUSE rules

62 Volume Management for the XP128/XP1024amount of free space are available in one VDEV. For other RAID levels, a maximum of 256 FVs and a certain amo

Pagina 60 - VSC operations

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 63Restrictions• The LDEV must not have a path definition, including TrueCopy

Pagina 61 - Parity group configuration

64 Volume Management for the XP128/XP1024As defined in Table 19, VSC does not work with OPEN-L and OPEN-M emulation types. VSC supports OPEN-3, OPEN-8

Pagina 62 - Volume to Space operation

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 65Volume Initialize and Make Volume operationsThe Volume Initialize and the

Pagina 63 - Restrictions

66 Volume Management for the XP128/XP1024LUSE operationsUsers belonging to the Administrator and StorageAdmin groups can perform Modify VSC and Modify

Pagina 64

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 67• Emulation: The emulation type of the LDEV. If the selected LDEV is a VSC

Pagina 65

68 Volume Management for the XP128/XP1024• PG: A combination of the disk group and the parity group. If the LDEV extends over two or more parity group

Pagina 66 - LUSE operations

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 69If you select a LUSE volume as the top LDEV, the Volume Count list is unav

Pagina 67 - Free LDEVs table

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 717 Port operation restrictions . . . . . . . . . . . . . . . . . . . . . .

Pagina 68 - Expanded LDEVs list

70 Volume Management for the XP128/XP1024Creating a LUSE volume using the LDEV information tableCAUTION: Creating a LUSE volume destroys existing data

Pagina 69

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 71If the XP disk array has firmware version 21.06.22 or later installed, you

Pagina 70 - Changing LUSE capacities

72 Volume Management for the XP128/XP1024The status of each parity group is indicated by one of the following icons.The status of each VDEV is indicat

Pagina 71 - VSC Operations

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 73Capacity unit listThe Capacity Unit list allows you to select the unit (MB

Pagina 72 - Parity Group - LDEV table

74 Volume Management for the XP128/XP10242. Select one or more LDEVs (normal or custom volumes) you want to convert to space.For the OPEN-V emulation

Pagina 73 - Capacity unit list

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 75If the VDEV you selected is not an OPEN-V volume, the Install CV pane (1)

Pagina 74

76 Volume Management for the XP128/XP1024b. Select one of methods by clicking Specify capacity and number, Divide free space by number, Divide free sp

Pagina 75

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 77The Install CV function allocates custom volumes in the order in which the

Pagina 76

78 Volume Management for the XP128/XP10245. After configuring custom volumes, click Next. The Install CV pane (2) is displayed.Figure 39 Install CV pa

Pagina 77

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 79NOTE: The CU number of another SLPR is used check box is displayed only wh

Pagina 79

80 Volume Management for the XP128/XP1024If the boundary area of the selected LDEV number has an SSID, the Install CV confirmation dialog box is displ

Pagina 80

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 8115.Verify that the information in the Install CV confirmation dialog box i

Pagina 81

82 Volume Management for the XP128/XP10242. Right-click any part of the Parity Group - LDEV tree and select Make Volume. The Make Volume pane (1) appe

Pagina 82

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 83d. Click Set. The pane displays the setting in the table.Figure 44 Make Vo

Pagina 83

84 Volume Management for the XP128/XP1024NOTE: If no CV is set, the Make Volume operation does not create a volume in the VDEV. In this case, a messag

Pagina 84

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 85NOTE: The CU number of another SLPR is used check box is displayed only wh

Pagina 85

86 Volume Management for the XP128/XP102414.Verify that the information is correct and click OK. The Customized Volume pane is displayed. The created

Pagina 86

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 872. Right-click any part of the Parity Group - LDEV tree and select Volume

Pagina 87

88 Volume Management for the XP128/XP1024NOTE: The CU number of another SLPR is used check box is displayed only when you logged in as a user in the S

Pagina 88

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 89NOTE: The SSID of another SLPR is used check box is displayed only when yo

Pagina 89 - Formatting LDEVs

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 9About this guideThis guide provides information about:• ”LUN Manager for th

Pagina 90

90 Volume Management for the XP128/XP1024Formatting all blocked volumesUse the All Format pane to format all blocked volumes in parity groups in the l

Pagina 91

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 91IndexNumerics16-Port FC/CA CHIP 162 port mode 22, 47AaddressesFibre Channe

Pagina 92

92authentication 26, 51iSCSI status, checking 25modes 18mutual authentication 53pinging in iSCSI environment 49registering in host groups 35registerin

Pagina 93

LUN Configuration and Security Manager XP user guide for the XP128/XP1024 93OOPEN volumes, LUSE rules 59OPEN-VInstall Custom Volume function 63LUSE ru

Pagina 94

94Customized Volume pane 71defined 60Install CV function 63, 74Make Volume function 65, 81restrictions 90samples 61starting 71Volume Initialize functi

Pagina 95

Figures1 LU paths configuration in a Fibre Channel environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 LU paths con

Pagina 97

Tables1 Recommended and minimum firmware versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Document conven

Comentarios a estos manuales

Sin comentarios