Chapter 4 Installing Mass Storage Devices
29
NOTE The boot order can be changed using the Server's (BIOS) Setup
Utility and the Qlogic SCSI Utility. Refer to Chapter 10,
"Configuring the HP Server" for more information.
Tools Required
The following tools are required for the removal and installation of mass storage
devices in the HP Server:
Phillips (cross-head) screwdriver (#2).
Small flat-bladed screwdriver.
Jumper-removal tool or needle-nosed pliers.
Antistatic wrist strap and conductive foam pad (recommended).
Pen or pencil.
Equipment log: to record the model and serial numbers of components.
Installing a Hot Swap Hard Drive
The HP Server supports a variety of single-ended SCSI SCA-type hard disk
drives. The area of the chassis below the system’s controls and indicators on the
front panel houses up to two 3.5-inch bays. Each bay can contain a single
industry-standard SCSI-2 or SCSI-3, one-inch high hard disk drive from the
factory. The procedures in this section describe how to determine drive status,
remove a faulty drive, and install a new drive.
Determining Drive Status
Status LEDs arranged in sets of three over each of the two Hard Disk Bays
monitor the status of each drive.