Chapter 8 Server Management Boards
83
• Secure mode control, including video blank option monitoring and control
and front panel lock/unlock initiation.
• IPMI Management Controller Initialization Agent
• Magic Packet and Wake on LAN / Power on LAN support
• Emergency Management Port (EMP) interface
Intelligent Chassis Management Bus (ICMB) Controller
The ICMB Controller resides on the Legacy I/O Board. It serves as a
bridge between the internal Intelligent Platform Management Bus (IPMB)
and the external Intelligent Chassis Management Bus (ICMB). The internal
IPMB transports server management information within a system, and the
external ICMB transports server management information between various
chassis in a server(s) and peripherals cluster configuration.
Hot Swap Controller (HSC)
The Hot Swap Controller (HSC) resides on the Power Distribution Board (T-
Docking). The primary functions of the HSC are as follows:
• Implements the SAF-TE command set
• Controls the fault lights
• Provides a path for management information via SCSI
• Retrieves drive fault status, Backplane temperature, and fan failure
information via IPMB
• Queries the status of the power distribution board by retrieving information
from the BMC via the IPMB
• Controls drive power-on and power-down, facilitating hot-swapping.