Chapter 13 Alternative Rack Mounting (4–Post)
119
A tension spring allows the outer-rails to compress during installation. The
outer-rails are held in place at of the front of the rack by a flat spring tab at
the rear face of the front columns. See Figures 13-2 and 13-5.
6. Repeat Steps 3 through 5 for the outer-rail assembly on the right front and rear
columns.
7. If you need to release the outer-rail assembly once installed into the rack, do
the following:
a. Place your finger inside the rail at the point shown by the arrow to release
the spring tab. See Figure 13-5.
b. Press in on the spring tab and pull the outer-rail assembly toward you at
the front of the rack. See Figure 13-5.
Spring Tab
V
iew Rotated 90 Degrees CCW
Figure 13-5. Releasing the Outer-Rail Assembly