Hp ProLiant BL25p G2 Server-Blade Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 99
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
Component identification 9
Online/activity LED
(green)
Fault/UID LED
(amber/blue)
Interpretation
Flashing irregularly Off The drive is active, and it is operating normally.
Off Steadily amber
A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon as
possible.
Off
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off Off
The drive is offline, a spare, or not configured as part of an
array.
System board components
Item Description
1 T-15 Torx screwdriver
2 Power converter module
3 FC mezzanine connectors (2)
4 NIC mezzanine connector
5 System maintenance switch (SW4)
6 Processor 2 memory bank D
7 Processor 2 memory bank C
8 DIMM slots 5-8
9 Processor socket 2
10 Fan connectors (5)
11 Front panel/LED board connector
12 Processor socket 1 (shown populated)
13 DIMM slots 1-4
14 Processor 1 memory bank A
15 Processor 1 memory bank B
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 98 99

Comentarios a estos manuales

Sin comentarios