
Hardware options installation 54
9.
Power up the server (on page 16).
After installing the DIMMs, use RBSU ("HP ROM-Based Setup Utility" on page 81) to configure the memory
protection mode.
Processor option
The server supports single-processor and dual-processor operations.
For more information about product features, specifications, options, configurations, and compatibility, see
the product QuickSpecs on the HP Product Bulletin website (http://www.hp.com/go/productbulletin).
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To avoid damage to the processor and system board, only authorized personnel
should attempt to replace or install the processor in this server.
CAUTION: To prevent possible server malfunction and damage to the equipment, multiprocessor
configurations must contain processors with the same part number.
CAUTION: To prevent possible server overheating, always populate processor socket 2 with a
processor and a heatsink or a processor socket cover and a heatsink blank.
IMPORTANT: If installing a processor with a faster speed, update the system ROM before
installing the processor.
IMPORTANT: Processor socket 1 must be populated at all times or the server does not function.
In a multiprocessor configuration, to optimize system performance, HP recommends balancing the total
capacity of the DIMMs across the processors.
To install the component:
1. Power down the server (on page 16).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 16).
o Remove the server from the rack (on page 17).
4. Remove the access panel (on page 18).
Comentarios a estos manuales