Specifications
Environmental specifications
Specification Value
Temperature range*
Operating 10°C to 35°C (50°F to 95°F)
Shipping -40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature 28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating 10% to 90%
Non-operating 5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Server specifications
Specification Value
Dimension
Height 17.6 cm (6.94 in)
Depth 67.3 cm (26.5 in)
Width 48.3 cm (19.0 in)
Maximum weight (all hard
drives, power supplies, and
processors installed)
43 kg (95 lb)
Minimum weight (one hard
drive, one power supply, and
one processor installed)
36 kg (79 lb)
Input requirement
Rated input voltage 100-127 VAC
200-240 VAC
Rated input frequency 50-60 Hz
Rated input current @ 100 VAC–12A
@ 200 VAC–8A
Rated input power @100 VAC–1161 W
@200 VAC–1598 W