Hardware options installation 36
4.
Remove the tray with the I/O enabler board.
CAUTION: When installing the tray with the secondary processor memory board, be sure that all
DIMM latches on the primary processor memory board are in the fully-locked position. Failure to
do so results in damage to the primary processor memory board.
5. Install the tray with the secondary processor memory board.
6. Install the optional processors ("Installing a processor option" on page 37).
7. Install the DIMMs ("Installing DIMMs on the secondary processor memory board" on page 49).
8. Install the processor memory drawer cover.
9. Install the processor memory drawer.
10. Power up the server (on page 25).