Pagina 1 - User Guide

HP ProLiant ML310 Generation 2 Server User Guide February 2005 (First Edition) Part Number 378289-001

Pagina 2 - Audience Assumptions

10 HP ProLiant ML310 Generation 2 Server User Guide Item Description 5 Video connector 6 USB connectors (2) 7 RJ-45 Ethernet connector 8 Parallel

Pagina 3 - Contents

100 HP ProLiant ML310 Generation 2 Server User Guide

Pagina 4

Troubleshooting 101 ROMPaq Disaster Recovery If both the current and backup versions of the ROM are corrupt, perform ROMPaq disaster recovery proce

Pagina 5

102 HP ProLiant ML310 Generation 2 Server User Guide 8. Repeat steps 1 and 2. 9. Set positions 1, 4, 5, and 6 of the system maintenance switch to

Pagina 6

103 Regulatory Compliance Notices In This Section Regulatory Compliance Identification Numbers...

Pagina 7 - Front Panel Components

104 HP ProLiant ML310 Generation 2 Server User Guide Federal Communications Commission Notice Part 15 of the Federal Communications Commission (FCC

Pagina 8 - Front Panel LEDs and Buttons

Regulatory Compliance Notices 105 Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device,

Pagina 9 - Rear Panel Components

106 HP ProLiant ML310 Generation 2 Server User Guide • • • • Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 1

Pagina 10 - Rear Panel LEDs and Buttons

Regulatory Compliance Notices 107 Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) w

Pagina 11 - System Board Components

108 HP ProLiant ML310 Generation 2 Server User Guide Japanese Notice BSMI Notice Laser Compliance This product may be provided with an optical

Pagina 12

Regulatory Compliance Notices 109 WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in th

Pagina 13 - System Board LEDs

Server Component Identification 11 System Board Components Item Description Item Description 1 Mouse/keyboard connectors 10 Diskette drive c

Pagina 14

110 HP ProLiant ML310 Generation 2 Server User Guide Taiwan Battery Recycling Notice The Taiwan EPA requires dry battery manufacturing or importing

Pagina 15

111 Electrostatic Discharge In This Section Preventing Electrostatic Discharge...

Pagina 16 - SCSI IDs

112 HP ProLiant ML310 Generation 2 Server User Guide Grounding Methods to Prevent Electrostatic Discharge Several methods are used for grounding. U

Pagina 17

113 Server Specifications In This Section Server Specifications ...

Pagina 18

114 HP ProLiant ML310 Generation 2 Server User Guide Operating 10°C to 35°C (50°F to 95°F) Shipping -10°C to 60°C (14°F to 140°F) Maximum wet bul

Pagina 19 - Identifying Fans

115 Technical Support In This Section Related Documents...

Pagina 20

116 HP ProLiant ML310 Generation 2 Server User Guide Before You Contact HP Be sure to have the following information available before you call HP:

Pagina 21 - Server Operations

117 Acronyms and Abbreviations ABEND abnormal end ACU Array Configuration Utility ASR Automatic Server Recovery DDR double data rate DIMM dua

Pagina 22 - Removing the Access Panel

118 HP ProLiant ML310 Generation 2 Server User Guide iLO Integrated Lights-Out IML Integrated Management Log IPL initial program load IRQ interr

Pagina 23 - Server Operations 23

Acronyms and Abbreviations 119 NVRAM non-volatile memory ORCA Option ROM Configuration for Arrays PCI-X peripheral component interconnect extended

Pagina 24

12 HP ProLiant ML310 Generation 2 Server User Guide Position Description Function S1 Reserved Reserved S2 Configuration lock Off = System confi

Pagina 25 - Server Setup

120 HP ProLiant ML310 Generation 2 Server User Guide SAS serial attached SCSI SATA serial advanced technology attachment SDRAM synchronous dynami

Pagina 26 - Rack Planning Resources

121 components 7 Index configuration of system 35, 36, 61 Configuration Replication Utility 63 connection problems 85 connectors 7 cont

Pagina 27 - Optimum Environment

122 HP ProLiant ML310 Generation 2 Server User Guide fan zones 18 installing hardware 37 fans 19 installing operating system 36 features

Pagina 28 - Temperature Requirements

Index 123 Option ROM Configuration for Arrays (ORCA) 66 registering the server 36 regulatory compliance notices 103 options installation 33

Pagina 29 - Power Requirements

124 HP ProLiant ML310 Generation 2 Server User Guide system configuration settings 11 system maintenance switch 11 system power connector 11

Pagina 30 - Rack Warnings and Cautions

Server Component Identification 13 System Board LEDs Item LED Description Status 1 PPM error Off = Normal Amber = PPM failed or missing 2 Mu

Pagina 31 - Server Setup 31

14 HP ProLiant ML310 Generation 2 Server User Guide Item LED Description Status 8 Power good Off = Normal Green = Power failed 9 Processor fail

Pagina 32

Server Component Identification 15 System LED and Color Internal Health LED Color Status PPM failure, slot X (Amber) Red • • PPM in slot X has fail

Pagina 33 - Setting up a Tower Server

16 HP ProLiant ML310 Generation 2 Server User Guide SCSI IDs Item Description 0 SCSI ID 0 1 SCSI ID 1 2 SCSI ID 2 3 SCSI ID 3

Pagina 34

Server Component Identification 17 Hot-Plug SCSI Hard Drive LEDs Item LED Description Status 1 Activity status On = Drive activity Flashing =

Pagina 35 - Server Setup 35

18 HP ProLiant ML310 Generation 2 Server User Guide Hot-Plug SCSI Hard Drive LED Combinations Activity LED (1) Online LED (2) Fault LED (3) In

Pagina 36 - Registering the Server

Server Component Identification 19 Identifying Fans Item Description 1 System fan 2 Processor fan

Pagina 37 - Introduction

© Copyright 2005 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows NT are US registered trademarks of Microsoft Corporation.

Pagina 39

21 Server Operations In This Section Powering Up the Server...

Pagina 40

22 HP ProLiant ML310 Generation 2 Server User Guide Unlocking the Tower Bezel The removable tower bezel must be unlocked and opened before accessin

Pagina 41 - Memory Options

Server Operations 23 3. Open the tower bezel ("Unlocking the Tower Bezel" on page 22). 4. Loosen the two captive thumbscrews. 5. Slide

Pagina 43 - Hard Drive Options

25 Server Setup In This Section Optional Installation Services...

Pagina 44 - Non-Hot-Plug SATA Hard Drive

26 HP ProLiant ML310 Generation 2 Server User Guide − Linux − HP ProLiant Essentials (HP SIM and RDP) − VMWare • • Integrated hardware and softw

Pagina 45 - To replace the component:

Server Setup 27 − Coupling multiple racks • The Rack Products Documentation CD enables you to view, search, and print documentation for HP and C

Pagina 46 - Non-Hot-Plug SCSI Hard Drive

28 HP ProLiant ML310 Generation 2 Server User Guide CAUTION: To prevent improper cooling and damage to the equipment, do not block the ventilati

Pagina 47

Server Setup 29 The maximum recommended ambient operating temperature (TMRA) for most server products is 35°C (95°F). The temperature in the room

Pagina 48

3 Contents Server Component Identification 7 Front Panel Components...

Pagina 49

30 HP ProLiant ML310 Generation 2 Server User Guide • • • Do not allow the overall system AC current load to exceed 80 percent of the branch circui

Pagina 50 - SAS Controller

Server Setup 31 The leveling jacks are extended to the floor. • • • • • The full weight of the rack rests on the leveling jacks. The stabilizing f

Pagina 51 - Removing the CD-ROM Drive

32 HP ProLiant ML310 Generation 2 Server User Guide Observe local occupational health and safety requirements and guidelines for manual material ha

Pagina 52 - DVD-ROM Drive

Server Setup 33 CAUTION: Do not operate the server for long periods without the access panel. Operating the server without the access panel res

Pagina 53 - Optional Diskette Drive

34 HP ProLiant ML310 Generation 2 Server User Guide 1. Connect peripheral devices to the server. WARNING: To reduce the risk of electric shock,

Pagina 54 - Expansion Boards

Server Setup 35 3. Connect the power cord to the AC power source. WARNING: To reduce the risk of electric shock or damage to the equipment: Do

Pagina 55 - Installing Expansion Boards

36 HP ProLiant ML310 Generation 2 Server User Guide Installing the Operating System To operate properly, the server must have a supported operating

Pagina 56

37 Hardware Options Installation In This Section Introduction ...

Pagina 57 - Server Cabling

38 HP ProLiant ML310 Generation 2 Server User Guide Processor and Heatsink CAUTION: Be sure that you have the current version of the system ROM

Pagina 58 - Non-Hot-Plug SCSI Cabling

Hardware Options Installation 39 6. Release the processor locking lever, and remove the processor. To replace the component: 1. Open the proces

Pagina 59 - Non-Hot-Plug SATA Cabling

4 HP ProLiant ML310 Generation 2 Server User Guide Hardware Options Installation 37 Introduction...

Pagina 60 - SAS Cabling

40 HP ProLiant ML310 Generation 2 Server User Guide CAUTION: To prevent possible server malfunction or damage to the equipment, be sure to compl

Pagina 61 - Configuration Tools

Hardware Options Installation 41 CAUTION: Heatsink retaining screws should be tightened in diagonally opposite pairs (in an "X" patte

Pagina 62

42 HP ProLiant ML310 Generation 2 Server User Guide • • • • All DIMMs installed must be the same speed. BIOS detects the DIMM population and sets t

Pagina 63 - HP ROM-Based Setup Utility

Hardware Options Installation 43 3. Open the DIMM slot latches. 4. Install the DIMM. 5. Install the access panel ("Removing the Access Pa

Pagina 64

44 HP ProLiant ML310 Generation 2 Server User Guide Non-Hot-Plug SATA Hard Drive To remove the component: 1. Power down the server. 2. Remove the

Pagina 65 - Array Configuration Utility

Hardware Options Installation 45 6. Remove the hard drive. To replace the component: 1. Install the non-hot-plug SATA hard drive into the drive

Pagina 66

46 HP ProLiant ML310 Generation 2 Server User Guide 2. Install the drive cage into the chassis, and secure with the six (6) Torx screws. 3. Conn

Pagina 67 - Management Tools

Hardware Options Installation 47 4. Remove the drive cage from the chassis. 5. Remove the six Torx screws that secure the drive cage to the cha

Pagina 68 - ROMPaq Utility

48 HP ProLiant ML310 Generation 2 Server User Guide 1. Install the non-hot-plug SCSI hard drive into the drive cage. 2. Install the drive cage i

Pagina 69 - Erase Utility

Hardware Options Installation 49 Hot-Plug SATA and SAS Hard Drives Hot-plug SATA and hot-plug SAS hard drives can be used interchangeably when a S

Pagina 70 - HP Systems Insight Manager

Contents 5 Array Diagnostic Utility ...72 HP

Pagina 71

50 HP ProLiant ML310 Generation 2 Server User Guide 2. Install the hard drive. 3. Determine the status of the hard drive from the hot-plug hard

Pagina 72 - Diagnostic Tools

Hardware Options Installation 51 4. Install the SAS controller, and press it down to seat. 5. Disconnect the SAS cable from the system board an

Pagina 73 - Keeping the System Current

52 HP ProLiant ML310 Generation 2 Server User Guide 4. Push up on the release lever and push the drive partially out through the front of the serv

Pagina 74 - Resource Paqs

Hardware Options Installation 53 3. Slide the DVD-ROM drive into the DVD-ROM drive bay. 4. Secure the DVD-ROM drive cable to the DVD-ROM drive

Pagina 75 - Care Pack

54 HP ProLiant ML310 Generation 2 Server User Guide 1. Power down the server. 2. Slide the diskette drive into the diskette drive bay. 3. Secu

Pagina 76

Hardware Options Installation 55 3. Remove the expansion slot cover. CAUTION: To prevent improper cooling and thermal damage, do not operate

Pagina 77 - Battery Replacement

56 HP ProLiant ML310 Generation 2 Server User Guide 4. Install the expansion board, and press it down to seat. 5. Connect any required internal

Pagina 78 - 5. Remove the battery

57 Server Cabling In This Section Server Cabling...

Pagina 79 - Troubleshooting

58 HP ProLiant ML310 Generation 2 Server User Guide Item Cable Description 2 SCSI cable Non-Hot-Plug SCSI Cabling Item Cable Description 1 SC

Pagina 80 - Important Safety Information

Server Cabling 59 Hot-Plug SATA Cabling Item Cable Description 1 Power cable 2 SATA cable Non-Hot-Plug SATA Cabling

Pagina 81 - Warnings and Cautions

6 HP ProLiant ML310 Generation 2 Server User Guide European Union Regulatory Notice...

Pagina 82

60 HP ProLiant ML310 Generation 2 Server User Guide Item Cable Description 1 SATA cable 2 Power cable SAS Cabling Item Cable Description 1

Pagina 83 - Troubleshooting 83

61 Server Software and Configuration Utilities In This Section Configuration Tools...

Pagina 84 - Symptom Information

62 HP ProLiant ML310 Generation 2 Server User Guide • Testing server hardware using the Insight Diagnostics Utility ("HP Insight Diagnostics&

Pagina 85 - Diagnostic Steps

Server Software and Configuration Utilities 63 Configuration Replication Utility ConRep is shipped in the SmartStart Scripting Toolkit and is a pr

Pagina 86 - Start Diagnosis Flowchart

64 HP ProLiant ML310 Generation 2 Server User Guide • • • To access RBSU, press the F9 key during power up when prompted in the upper right corner

Pagina 87 - Troubleshooting 87

Server Software and Configuration Utilities 65 For more information, refer to the HP ROM-Based Setup Utility User Guide on the Documentation CD or

Pagina 88 - General Diagnosis Flowchart

66 HP ProLiant ML310 Generation 2 Server User Guide The minimum display settings for optimum performance are 800 × 600 resolution and 256 colors. T

Pagina 89 - Troubleshooting 89

Server Software and Configuration Utilities 67 The intuitive graphical user interface of the Altiris Deployment Solution console provides simplifi

Pagina 90 - Power-On Problems Flowchart

68 HP ProLiant ML310 Generation 2 Server User Guide Automatic Server Recovery...

Pagina 91 - Troubleshooting 91

Server Software and Configuration Utilities 69 System Online ROM Flash Component Utility The Online ROM Flash Component Utility enables system adm

Pagina 92

7 Server Component Identification In This Section Front Panel Components ...

Pagina 93 - POST Problems Flowchart

70 HP ProLiant ML310 Generation 2 Server User Guide • You encounter an error when completing the steps of a factory-installed operating system ins

Pagina 94

Server Software and Configuration Utilities 71 USB Support HP provides both standard USB support and legacy USB support. Standard support is provi

Pagina 95 - OS Boot Problems Flowchart

72 HP ProLiant ML310 Generation 2 Server User Guide Diagnostic Tools List of Tools: Survey Utility ...

Pagina 96

Server Software and Configuration Utilities 73 HP Insight Diagnostics The HP Insight Diagnostics utility displays information about the server har

Pagina 97 - Troubleshooting 97

74 HP ProLiant ML310 Generation 2 Server User Guide Change Control and Proactive Notification...

Pagina 98

Server Software and Configuration Utilities 75 ProLiant Support Packs PSPs represent operating system-specific bundles of ProLiant optimized drive

Pagina 100

77 Battery Replacement If the server no longer automatically displays the correct date and time, you may need to replace the battery that provide

Pagina 101 - Manual Recovery

78 HP ProLiant ML310 Generation 2 Server User Guide 5. Remove the battery. IMPORTANT: Replacing the system board battery resets the system ROM t

Pagina 102 - Other Information Resources

79 Troubleshooting In This Section Server Diagnostic Steps...

Pagina 103

8 HP ProLiant ML310 Generation 2 Server User Guide Item Description 2 Power LED 3 Hard Drive activity LED 4 NIC LED 5 Internal health LED 6 USB c

Pagina 104 - Class A Equipment

80 HP ProLiant ML310 Generation 2 Server User Guide Important Safety Information Familiarize yourself with the safety information in the following

Pagina 105 - Class B Equipment

Troubleshooting 81 This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury

Pagina 106 - Modifications

82 HP ProLiant ML310 Generation 2 Server User Guide WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: Th

Pagina 107

Troubleshooting 83 Observe local occupation health and safety requirements and guidelines for manual handling. • • • • Obtain adequate assistance to

Pagina 108 - Laser Compliance

84 HP ProLiant ML310 Generation 2 Server User Guide 5. Disconnect any peripheral devices not required for testing (any devices not necessary to po

Pagina 109 - Battery Replacement Notice

Troubleshooting 85 Service Notifications To find out the latest service notifications, refer to the HP website (http://www.hp.com/products/servers/p

Pagina 110

86 HP ProLiant ML310 Generation 2 Server User Guide The available flowcharts include: • Start Diagnosis Flowchart (on page 86) • General Diagnosi

Pagina 112 - Discharge

88 HP ProLiant ML310 Generation 2 Server User Guide General Diagnosis Flowchart The General Diagnosis flowchart provides a generic approach to trou

Pagina 114

Server Component Identification 9 Item Description Status 3 Hard drive activity LED Green = Hard drives are properly connected and functioning Of

Pagina 115 - Technical Support

90 HP ProLiant ML310 Generation 2 Server User Guide Power-On Problems Flowchart Symptoms: • • • • • • • • • • The server does not power on. The sys

Pagina 116 - Before You Contact HP

Troubleshooting 91 Item Refer to 7 • "Power Supply Problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentati

Pagina 117 - Acronyms and Abbreviations

92 HP ProLiant ML310 Generation 2 Server User Guide

Pagina 118

Troubleshooting 93 POST Problems Flowchart Symptoms: • • • • • Server does not complete POST NOTE: The server has completed POST when the system at

Pagina 119

94 HP ProLiant ML310 Generation 2 Server User Guide

Pagina 120

Troubleshooting 95 OS Boot Problems Flowchart Symptoms: • • • • Server does not boot a previously installed operating system Server does not boot Sm

Pagina 121

96 HP ProLiant ML310 Generation 2 Server User Guide Item Refer to 8 • "Hardware Problems" in the HP ProLiant Servers Troubleshooting Gu

Pagina 122

Troubleshooting 97

Pagina 123

98 HP ProLiant ML310 Generation 2 Server User Guide Server Fault Indications Flowchart Symptoms: • Server boots, but a fault event is reported by

Pagina 124

Troubleshooting 99 Item Refer to 8 • "Hardware Problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation C