Installing Hardware Options, Server Power Off
Installing the Integrated Array Bypass
Use the Integrated Array Bypass kit to bypass the Smart Array 5i Controller and use
an optional controller.
The Smart Array 5i Controller is routed to the internal drives through a daughter
board, the Array Enabler board, in the I/O module.
The Integrated Array Bypass kit allows you to replace the Array Enabler board with a
connector and cable that you can connect to an optional controller board.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the
internal system components to cool before touching them.
CAUTION: Back up your data each time you move drive arrays or change the
configuration.
To install the Integrated Array Bypass assembly:
1. If you have not powered up the server for the first time, skip to step 4. If you
have powered up the server, back up the server data.
2. Shut down the operating system as directed in the operating system instructions.
3. Power down the server (refer to Chapter 7).
4. Disconnect the power cords from the server.
5. Slide the server out of the rack.
6. Open the I/O lid as shown in Chapter 3.
4-18 HP ProLiant DL760 Generation 2 Server User Guide
HP CONFIDENTIAL
Writer: Jennifer Hayward File Name: e-ch4 Installing Options-Power Off.doc
Codename: Pioneer Part Number: 201264-002 Last Saved On: 6/17/03 9:32 AM