Installing Hardware Options, Hot-Pluggable
Power Supply LED Indicators
Each power supply has status and AC power LEDs. Refer to Figure 5-19 and
Table 5-4 for a detailed description of both indicators.
Figure 5-19: Power supply LEDs
Table 5-4: Power Supply LEDs
Item Condition Meaning
Green Normal operation
Green/Amber alternating Power supply failed to restart after a prolonged fault.
Green blinking Power supply will restart within 20 seconds.
Amber Fault detected in this power supply.
Amber blinking Power supply failed self-test.
1 Status
Off No AC power is connected to this power supply.
Off System is in standby mode, or interlocks are disabled.
Green AC power is connected to this power supply. 2 AC Power
HP ProLiant DL760 Generation 2 Server User Guide 5-39
HP CONFIDENTIAL
Writer: Bryce Miller File Name: f-ch5 Installing Options-Hot Pluggable.doc
Codename: Comet Part Number: 201264-001 Last Saved On: 6/17/03 9:47 AM