For the latest product & technical information, refer to the Information Sources on pages 2 and 3.
Updated 03/22/01
IBM NETFINITY 7100
Netfinity 7100 Internal SCSI Cabling
The Netfinity 7100 contains a DASD backplane supporting 10 hot-swap, SCA-2 compliant drive bays. The backplane is connected to Channel B of the integrated
dual-channel, Wide Ultra2 SCSI controller through a 16-bit LVD SCSI cable. Channel A only supports external SCSI attachment and is cabled directly to the external
0.8mm VHDCI SCSI connector. To support devices in the internal 133/89mm (5.25/3.5in) half-high bays, a two-drop, 16-bit LVD SCSI cable with integrated terminator
is included with the server. This cable can be used to connect to an optional SCSI adapter or, in the case of RAID configurations where the backplane cable is
attached to an optional RAID adapter, it can be connected to the Channel B connector.
Bay Form
Factor
Height Front
Access
Usage Part
Number
Description RPM Height Bays
Supported
Max
Qty
-
89mm
(3.5in)
SL Yes Diskette
Ultra160 Hard Disk Drives (HDD)
1
-
133mm
(5.25in)
HH Ye s
IDE CD-
ROM
37L7201
9.1GB Ultra160 SCSI Hot-Swap
SL HDD
7200 SL See diagram 10
RM 1
133mm
(5.25in)
HH
1
Ye s O p e n 3 7 L 7 2 0 2
18.2GB Ultra160 SCSI Hot-Swap
SL HDD
7200 SL See diagram 10
RM 2
133mm
(5.25in)
HH
1
Ye s Open 37L7203
36.4GB Ultra160 SCSI Hot-Swap
SL HDD
7200 SL See diagram 10
1 . . . 10
or
1 ... 7
HS SL or HH
2
Ye s O p e n 3 7L 7 2 0 4
9.1GB 10K-4 Ultra160 SCSI Hot-
Swap SL HDD
10,000 SL See diagram 10
NB3
3
19in Rack 3U Ye s Open 37L7205
18.2GB 10K-4 Ultra160 SCSI Hot-
Swap SL HDD
10,000 SL See diagram 10
1. Two half-high (HH) bays can be combined to support a single full-
high (FH) device.
2. The top bay is HH; all others are configured in groups of three SL
bays. When a HH drive is installed in one of these groups, only another
HH or a single SL drive can be installed in the same group. For clarity,
the SCSI IDs are identified.
3. Tower configured systems support installation of up to three
NetBAY3s. See IBM Netfinity NetBAY3 Stackable Enclosure section for
supported devices.
37L7206
36.4GB 10K-4 Ultra160 SCSI Hot-
Swap SL HDD
10,000 SL See diagram 10
19K0655
9.1GB 15Krpm Ultra160 SCSI Hot-
Swap HDD
15,000 SL See diagram 10
19K0656
18.2GB 15Krpm Ultra160 SCSI
Hot-Swap HDD
15,000 SL See diagram 10
External Storage
Expansion Units
2
Form Factor
35311RU EXP300 Storage Expansion Unit
3
Rack (3U)
09N7296
EXP300 Rack-to-Tower
Conversion Kit
-
35601RU
FAStT EXP500 Storage Expansion
Unit
4
Rack (3U)
35421RU FAStT200 Storage Server
5, 6
Rack (3U)
35422RU FAStT200 HA Storage Server
5
Rack (3U)
19K1121
FAStT200 Redundant RAID
Controller
-
1. Netfinity 7100 contains an Ultra2 hot-swap backplane which limits Ultra160
HDDs to Ultra2 bus speeds.
2. Not supported by the onboard external SCSI port. To configure a SCSI
storage device, select an optional SCSI controller then refer to Appendix D:
Cables - Storage Units - Controllers to confirm the controller supports the
desired External Storage Expansion Unit and to select a supported cable. For
HDD or other expansion unit options, see the specific expansion unit section.
For Fibre Channel storage devices, refer to the Fibre Array Solutions section.
3. EXP300 includes a single 2M Ultra2 SCSI cable and dual hot-swap 500W
power supplies, each with its own power cord. To convert an EXP300 to a tower
form factor, Netfinity EXP300 Rack-to-Tower Conversion Kit (P/N 09N7296) is
required.
4. FAStT EXP500 Storage Expansion Unit (P/N 35601RU) includes dual hot-
swap 350W power supplies, each with its own power cord.
5. The FAStT200 includes two hot-swap, 350W auto-ranging redundant power
supplies, each with its own power cord.
6. Can be upgraded to FAStT200 HA Storage Server through the addition of a
FAStT200 Redundant RAID Controller (P/N 19K1121).
Diskette
Bay 1
CD-ROM
Bay 2
HH
0
4
SL
14
8
2
12
10
1
4
3
0
14
10
9
5
13
11
Removable
Media (RM)
Bays
Hot-Swap (HS)
Bays 10 x SL
-or-
7 x HH
(SCSI IDs
shown)
Netfinity NetBAY3 (NB3)
(Optional on Tower Configurations)
1. The top bay is HH; all others are configured in groups of three SL
bays. When a HH drive is installed in one of these groups, only another
HH or a single SL drive can be installed in the same group. For clarity,
the SCSI IDs are identified.