HP A5799A Manual de usuario Pagina 139

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 166
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 138
129
.MAXRETRY
This event is generated by PHONHOME, PHSYSOP, or PAGE. It will
occur after the value entered for the Max. Retries system parameter is
surpassed.
Example:
Alarm/Event Action Routine Parameters Comments
.MAXRETRY PHONHOME 2
This example initiates a PHONHOME to Home Phone Number 2, as
defined in the System Parameter table, when the maximum retry
counter has been exceeded.
.MDMINITERR
This alarm is generated when a modem initialization error occurs.
Alarm/Event Action Routine Parameters Comments
.MDMINITERR SNMPTRAP 1 Modem error
.MEMLOW
The alarm .MEMLOW is generated on the hour if fewer than 4KB (4096
bytes) are available on the Terminal server variable area.
Example:
Alarm/Event Action Routine Parameters Comments
.MEMLOW PHONHOME Memory low