142
Examples:
Alarm/Event Action Routine Parameters Comments
.AUTHFAIL PAGE
This example calls a pager at the default number, when an authorization
failure occurs, and delivers the default message to the pager.
Alarm/Event Action Routine Parameters Comments
.BAT48LOW PAGE 5551324,9990001
This example calls a pager at the number 555-1324 and delivers the
message "9990001" when the battery voltage falls below the set limit.
PHONHOME Action
Routine
The PHONHOME Action Routine places a call to a specified number
and delivers a Terminal server alarm message when the call is
complete.
Format:
PHONHOME
Resource Required
: Modem
Parameters:
phone number
1 to 3 -
For home phone number 1, 2, or 3 (from system
parameters
)
or
Phone Number to call -
Phone number to call. If omitted, Home
Phone Number 1 is used.
Examples:
Alarm/Event Action Routine Parameters Comments
.HOURLY-2 PHONHOME