Appendix D: Insight SNMP rules 177
Appendix D: Insight SNMP rules
Insight SNMP rules
The following tables list all of the HP rules delivered with the rules file for Netcool/OMNIbus version
5.0 that relate to specific SNMP events. The rules and corresponding events are organized by MIB
type and object identifier.
CR3500 RAID controller (CPQCR.MIB)
Trap name OID () Caused by Cleared by
New in revision
5.0
CpqCrController1FailureTrap 1 2
CpqCrController1InformationTrap 2
CpqCrController2FailureTrap 3 4
CpqCrController2InformationTrap 4
CpqCrLogDriveInformationTrap 5
CpqCrLogDriveFailureTrap 6 5
CpqCrLogDriveReconstructTrap 7 5
CpqCrLogDriveReducedTrap 8 5
CpqCrLogDriveInitializingTrap 9 5
CpqCrDiskInformationTrap 10
CpqCrDiskFailureTrap 11 10
CpqCrDiskReconstructTrap 12 13, 14
CpqCrDiskAvailableTrap 13 14
CpqCrDiskSpareTrap 14
CpqCrEMUNormalTrap 15
CpqCrEMUFanFailureTrap 16 17
CpqCrEMUFanInformationTrap 17
CpqCrEMUPowerSupplyFailureTr
ap
18 19
CpqCrEMUPowerSupplyInformati
onTrap
19
CpqCrExpCabFanFailureTrap 20 21
CpqCrExpCabFanInformationTrap 21
CpqCrExpCabPowerSupplyFailur
eTrap
22 29
CpqCrEMUTemperatureMinor
(3)Trap
23 25